Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MC24-2.4-AAC/DC CONVERTER 24V 58W |
0 |
|
![]() Datasheet |
Linear C | Bulk | Obsolete | Linear | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 2.4 A | - | - | - | - | - | 58W | Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.63" L x 4.88" W x 2.50" H (143.0mm x 124.0mm x 63.5mm) |
![]() |
1010976NXT-100-1002,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 3.3V | - | - | - | - | - | 20 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
1010975NXT-100-1001,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 2.5V | - | - | - | - | - | 20 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
1010978NXT-100-1004,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 12V | - | - | - | - | - | 8.3 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
1010980NXT-100-1006,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 4.2 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
1010979NXT-100-1005,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 15V | - | - | - | - | - | 6.7 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
1010982NXT-100-1008,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 48V | - | - | - | - | - | 2.1 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
1010981NXT-100-1007,RE |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC | 28V | - | - | - | - | - | 3.6 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.50" L x 2.50" W x 1.00" H (114.3mm x 63.5mm x 25.4mm) |
![]() |
MINT2270A1976E01AC/DC CONVERTER 5V 24V 270W |
0 |
|
![]() Datasheet |
MINT2270A (270W) | Bulk | Obsolete | Open Frame | 2 | 100 ~ 240 VAC | 5V | 24V | - | - | - | - | 200 mA | 11.3 A | - | - | - | - | 270W | Medical | 4 kV | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off, Remote Sense | Chassis Mount | 7.17" L x 3.35" W x 1.17" H (182.0mm x 85.0mm x 29.6mm) |
![]() |
1010971CHCONXT-100-1005 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 15V | - | - | - | - | - | 6.7 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010970CHCONXT-100-1004 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 12V | - | - | - | - | - | 8.3 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010967CHCONXT-100-1001 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 2.5V | - | - | - | - | - | 20 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010973CHCONXT-100-1007 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 28V | - | - | - | - | - | 3.6 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010969CHCONXT-100-1003 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 5V | - | - | - | - | - | 20 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010972CHCONXT-100-1006 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 24V | - | - | - | - | - | 4.2 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010974CHCONXT-100-1008 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 48V | - | - | - | - | - | 2.1 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
1010968CHCONXT-100-1002 CHCO |
50 |
|
![]() Datasheet |
NXT-100 (100W) | Box | Active | Enclosed | 1 | 100 ~ 240 VAC | 3.3V | - | - | - | - | - | 20 A | - | - | - | - | - | 100W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 4.81" L x 2.59" W x 1.30" H (122.2mm x 65.8mm x 33.0mm) |
![]() |
GLC65HGAC/DC CONVERTER 3.3V 5V 12V 65W |
0 |
|
![]() Datasheet |
GLC65 (65W) | Bulk | Obsolete | Open Frame | 3 | 90 ~ 264 VAC | 3.3V | 5V | 12V | - | - | - | 5 A | 4 A | 2.5 A | - | - | - | 65W | ITE (Commercial) | - | 0°C ~ 50°C | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) |
|
MPB125-2005GAC/DC CONVERTER 5V 12V 125W |
0 |
|
![]() Datasheet |
MPB125 (125W) | Bulk | Obsolete | Open Frame | 2 | 90 ~ 264 VAC | 5V | 12V | - | - | - | - | 25 A | 500 mA | - | - | - | - | 125W | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.00" H (127.0mm x 76.2mm x 25.4mm) |
![]() |
VOF-120-48AC/DC CONVERTER 48V 120W |
0 |
|
![]() Datasheet |
VOF-120 (120W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 277 VAC | 48V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 120W | ITE (Commercial) | 3 kV | -20°C ~ 60°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.1mm) |