Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CUS150M-24/FAC/DC CONVERTER 24V 150W TDK-Lambda |
11 |
|
![]() Datasheet |
CUS150M (150W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 150W | ITE (Commercial), Medical | 4 kV | -20°C ~ 85°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 4.57" L x 2.52" W x 2.00" H (116.0mm x 64.0mm x 50.7mm) |
![]() |
CUS500M1-24AC/DC CONVERTER 24V 300W TDK-Lambda |
15 |
|
![]() Datasheet |
CUS500M1 (500W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 24V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 300W (502W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | - | Chassis Mount | 5.00" L x 3.00" W x 1.46" H (127.0mm x 76.2mm x 37.1mm) |
![]() |
CUS500M1-28AC/DC CONVERTER 28V 300W TDK-Lambda |
2 |
|
![]() Datasheet |
CUS500M1 (500W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 28V | - | - | - | - | - | 10.7 A | - | - | - | - | - | 300W (501W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | - | Chassis Mount | 5.00" L x 3.00" W x 1.46" H (127.0mm x 76.2mm x 37.1mm) |
![]() |
CUS200M-12/AAC/DC CONVERTER 12V 200W TDK-Lambda |
2 |
|
![]() Datasheet |
CUS200M (200-250W) | Bulk | Active | Enclosed | 1 | 85 ~ 265 VAC | 12V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 200W (200W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.50" L x 3.54" W x 1.69" H (139.7mm x 90.0mm x 43.0mm) |
![]() |
CUS400M-36/X5AC/DC CONVERTER 36V 250W TDK-Lambda |
13 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 36V | - | - | - | - | - | 6.94 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.04" L x 3.05" W x 1.56" H (128.0mm x 77.5mm x 39.5mm) |
|
ZWQ130-5223AC/DC CNVRTR 5V +/-12V 3.3V 130W TDK-Lambda |
13 |
|
![]() Datasheet |
ZWQ (130W) | Bulk | Active | Open Frame | 4 | 85 ~ 265 VAC | 5V | 12V | -12V | 3.3V | - | - | 15 A | 4 A | 4 A | 10 A | - | - | 130W | ITE (Commercial) | 3 kV | -10°C ~ 60°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.86" L x 4.17" W x 1.38" H (225.0mm x 106.0mm x 35.0mm) |
|
ZWQ130-5222AC/DC CNVRTR 5V +/-12V 12V 130W TDK-Lambda |
6 |
|
![]() Datasheet |
ZWQ (130W) | Bulk | Active | Open Frame | 4 | 85 ~ 265 VAC | 5V | 12V | -12V | 12V | - | - | 15 A | 4 A | 4 A | 4 A | - | - | 130W | ITE (Commercial) | 3 kV | -10°C ~ 60°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.86" L x 4.17" W x 1.38" H (225.0mm x 106.0mm x 35.0mm) |
![]() |
CUS400M-12/AX5AC/DC CONVERTER 12V 250W TDK-Lambda |
17 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 20.83 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.67" H (142.0mm x 90.0mm x 42.5mm) |
![]() |
CUS400M-24/AX5AC/DC CONVERTER 24V 250W TDK-Lambda |
14 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 10.42 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.67" H (142.0mm x 90.0mm x 42.5mm) |
![]() |
CUS400M-19/AX5AC/DC CONVERTER 19V 250W TDK-Lambda |
6 |
|
![]() Datasheet |
CUS400M (400W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 19V | - | - | - | - | - | 13.16 A | - | - | - | - | - | 250W (400W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.59" L x 3.54" W x 1.67" H (142.0mm x 90.0mm x 42.5mm) |