Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
NMP1K2-CKHEEH-04AC/DC CNVT 5V 48V 24V 12V 24V |
3,079 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 12V | 24V | - | 36 A | 5 A | 10 A | 40 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHEEK-04AC/DC CNVT 5V 48V 24V 12V 48V |
4,795 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 12V | 48V | - | 36 A | 5 A | 10 A | 40 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHHHC-04AC/DC CNVT 5V 48V 2X24V 5V 1200W |
3,735 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 24V | 5V | - | 36 A | 5 A | 10 A | 20 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHHHE-04ACDC CNVT 5V 48V 2X24V 12V 1200W |
2,289 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 24V | 12V | - | 36 A | 5 A | 10 A | 20 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHHHH-04AC/DC CNVT 5V 48V 3X24V 1200W |
4,242 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 24V | 24V | - | 36 A | 5 A | 10 A | 20 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHHHK-04ACDC CNVT 5V 48V 2X24V 48V 1200W |
3,342 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 24V | 48V | - | 36 A | 5 A | 10 A | 20 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHKKC-04AC/DC CNVT 5V 48V 24V 48V 5V |
4,986 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 48V | 5V | - | 36 A | 5 A | 10 A | 10 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHKKE-04AC/DC CNVT 5V 48V 24V 48V 12V |
3,902 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 48V | 12V | - | 36 A | 5 A | 10 A | 10 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHKKH-04AC/DC CNVT 5V 48V 24V 48V 24V |
2,551 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 48V | 24V | - | 36 A | 5 A | 10 A | 10 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKHKKK-04ACDC CNVT 5V 48V 24V 2X48V 1200W |
2,052 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 24V | 48V | 48V | - | 36 A | 5 A | 10 A | 10 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKCCC-04AC/DC CNVT 5V 2X48V 2X5V 1200W |
3,609 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 5V | 5V | - | 36 A | 5 A | 5 A | 72 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKCCE-04AC/DC CNVT 5V 2X48V 5V 12V 1200W |
3,888 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 5V | 12V | - | 36 A | 5 A | 5 A | 72 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKCCH-04AC/DC CNVT 5V 2X48V 5V 24V 1200W |
3,613 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 5V | 24V | - | 36 A | 5 A | 5 A | 72 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKCCK-04AC/DC CNVT 5V 2X48V 5V 48V 1200W |
4,399 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 5V | 48V | - | 36 A | 5 A | 5 A | 72 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKEEC-04AC/DC CNVT 5V 2X48V 12V 5V 1200W |
3,156 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 12V | 5V | - | 36 A | 5 A | 5 A | 40 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKEEE-04AC/DC CNVT 5V 2X48V 2X12V 1200W |
3,585 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 12V | 12V | - | 36 A | 5 A | 5 A | 40 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKEEH-04ACDC CNVT 5V 2X48V 12V 24V 1200W |
3,456 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 12V | 24V | - | 36 A | 5 A | 5 A | 40 A | 10 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKEEK-04ACDC CNVT 5V 2X48V 12V 48V 1200W |
4,524 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 12V | 48V | - | 36 A | 5 A | 5 A | 40 A | 5 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKHHC-04AC/DC CNVT 5V 2X48V 24V 5V 1200W |
4,254 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 24V | 5V | - | 36 A | 5 A | 5 A | 20 A | 36 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |
![]() |
NMP1K2-CKKHHE-04ACDC CNVT 5V 2X48V 24V 12V 1200W |
2,694 |
|
![]() Datasheet |
NMP (1200W) | Box | Active | Enclosed | 5 | 90 ~ 264 VAC, 120 ~ 370 VDC | 5V | 48V | 48V | 24V | 12V | - | 36 A | 5 A | 5 A | 20 A | 20 A | - | 1200W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Load Sharing, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.84" L x 5.00" W x 1.61" H (250.0mm x 127.0mm x 41.0mm) |