Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-HB0BAC-P-A-DK00000ACDC CNV 24V 5V 2X12V 5V 24V 5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 5V | 24V | 12V | 12V | 5V | 24V | 6 A | 3 A | 15 A | 15 A | 21 A | 8.3 A | 765W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GHCHHH-P-A-DK00000ACDC CNV 5V 24V 5V 24V 5V 24V 5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 24V | 24V | 5V | 24V | 24V | 5V | 3 A | 3 A | 6 A | 3 A | 8.3 A | 6 A | 720W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DGCBBB-P-A-DK00000AC/DC CNVT 3X12V 4X24V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 48V | 24V | 24V | 24V | 12V | 12V | 4.17 A | 3 A | 3 A | 8.3 A | 15 A | 15 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HHHGGH-P-A-DK00000ACDC CNVT 5V 3X24V 5V 2X24V 640W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 5V | 24V | 6 A | 3 A | 6 A | 3 A | 6 A | 3 A | 640W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HHHGHH-P-A-DK00000ACDC CNV 5V 24V 5V 24V 5V 2X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 5V | 24V | 6 A | 3 A | 6 A | 3 A | 6 A | 3 A | 620W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DCGGGG-P-A-DK00000AC/DC CONVERTER 6X24V 880W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 48V | 24V | 24V | 24V | 24V | 24V | 4.17 A | 8.3 A | 3 A | 3 A | 3 A | 3 A | 880W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-0DDDDD-P-A-DK00000AC/DC CONVERTER 5X48V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 5 | 85 ~ 264 VAC | 48V | 48V | 48V | 48V | 48V | - | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 4.17 A | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-ACCGHC-P-A-DK00000AC/DC CNVT 24V 5V 4X24V 925W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 5V | 24V | 24V | 24V | 24V | 5V | 21 A | 8.3 A | 8.3 A | 3 A | 3 A | 6 A | 925W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HHBDD0-P-A-DK00000AC/DC CNVT 2X48V 12V 2X5V 2X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 12V | 48V | 6 A | 3 A | 6 A | 3 A | 15 A | 4.17 A | 780W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-0000GC-P-A-DK00000AC/DC CONVERTER 3X24V 320W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 3 | 85 ~ 264 VAC | 24V | 24V | 24V | - | - | - | 3 A | 3 A | 8.3 A | - | - | - | 320W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DGDHDD-P-A-DK00000AC/DC CNVT 2X48V 5V 3X24V 48V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 48V | 24V | 24V | 48V | 5V | 24V | 4.17 A | 3 A | 3 A | 4.17 A | 6 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGHCDG-P-A-DK00000AC/DC CNVT 2X24V 48V 3X24V 5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 3 A | 3 A | 3 A | 3 A | 6 A | 3 A | 860W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GDDGGD-P-A-DK00000ACDC CNVT 48V 3X24V 48V 24V 960W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 48V | 48V | 24V | 24V | 3 A | 3 A | 4.17 A | 4.17 A | 3 A | 3 A | 960W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CGHGGG-P-A-DK00000AC/DC CONVERTER 6X24V 24V 780W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 24V | 24V | 24V | 5V | 24V | 24V | 8.3 A | 3 A | 3 A | 6 A | 3 A | 3 A | 780W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DDDDDD-P-A-DK00000AC/DC CONVERTER 6X48V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 6 | 85 ~ 264 VAC | 48V | 48V | 48V | 48V | 48V | 48V | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DDDDDH-P-A-DK00000AC/DC CNVT 5V 24V 4X48V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 48V | 48V | 48V | 48V | 48V | 5V | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 6 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DDDDD0-P-A-DK00000AC/DC CONVERTER 5X48V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 5 | 85 ~ 264 VAC | 48V | 48V | 48V | 48V | 48V | - | 4.17 A | 4.17 A | 4.17 A | 4.17 A | 4.17 A | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGHHHB-P-A-DK00000AC/DC CNVT 12V 5V 24V 5V 3X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 3 A | 3 A | 3 A | 3 A | 6 A | 3 A | 720W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GCCCCG-P-A-DK00000AC/DC CONVERTER 6X24V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 3 A | 3 A | 8.3 A | 8.3 A | 8.3 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGHGHH-P-A-DK00000AC/DC CNVT 5V 24V 5V 4X24V 660W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 3 A | 3 A | 3 A | 3 A | 6 A | 3 A | 660W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |