| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Part Status | Type | Number of Outputs | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Power (Watts) | Voltage - Output 4 | Voltage - Output 5 | Voltage - Input | Voltage - Output 6 | Current - Output 1 | Current - Output 6 | Current - Output 2 | Part Applications | Current - Output 5 | Current - Output 3 | Current - Output 4 | Voltage - Isolation | Operating Temperature | Features | Mounting Style | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CX10S-CCBBCG-P-A-DK00000AC/DC CNVT 3X24V 12V 24V 12V EXCELSYS / Advanced Energy |
4,196 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 24V | 24V | 12V | 1000W | 12V | 24V | 85 ~ 264 VAC | 24V | 8.3 A | 3 A | 8.3 A | ITE (Commercial), Medical | 8.3 A | 15 A | 15 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-BHA0HH-P-A-DK00000AC/DC CNVT 5V 24V 5V 24V 12V 5V EXCELSYS / Advanced Energy |
2,772 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 12V | 5V | 24V | 585W | 5V | 5V | 85 ~ 264 VAC | 24V | 15 A | 3 A | 6 A | ITE (Commercial), Medical | 6 A | 3 A | 21 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-BGCHDH-P-A-DK00000AC/DC CNVT 5V 24V 48V 5V 3X24V EXCELSYS / Advanced Energy |
2,275 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 12V | 24V | 24V | 900W | 24V | 5V | 85 ~ 264 VAC | 24V | 15 A | 3 A | 3 A | ITE (Commercial), Medical | 6 A | 3 A | 8.3 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-DBADDC-P-A-DK00000AC/DC CNVT 24V 2X48V 5V 2X12V EXCELSYS / Advanced Energy |
4,057 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 6 | 48V | 12V | 5V | 1000W | 48V | 48V | 85 ~ 264 VAC | 24V | 4.17 A | 8.3 A | 15 A | ITE (Commercial), Medical | 4.17 A | 21 A | 4.17 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-DABGHA-P-A-DK00000ACDC CNVT 2X5V 2X24V 5V 24V 810W EXCELSYS / Advanced Energy |
2,460 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 48V | 5V | 12V | 810W | 24V | 24V | 85 ~ 264 VAC | 5V | 4.17 A | 6 A | 21 A | ITE (Commercial), Medical | 3 A | 15 A | 3 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-DHHHHB-P-A-DK00000AC/DC CNVT 12V 5V 24V 2X5V 2X24V EXCELSYS / Advanced Energy |
4,130 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 48V | 5V | 24V | 780W | 5V | 24V | 85 ~ 264 VAC | 5V | 4.17 A | 6 A | 6 A | ITE (Commercial), Medical | 3 A | 3 A | 6 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-CHACAC-P-A-DK00000ACDC CNVT 24V 5V 24V 2X5V 24V 5V EXCELSYS / Advanced Energy |
2,268 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 24V | 5V | 24V | 910W | 5V | 24V | 85 ~ 264 VAC | 5V | 8.3 A | 21 A | 6 A | ITE (Commercial), Medical | 8.3 A | 3 A | 21 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-CCCCGG-P-A-DK00000AC/DC CONVERTER 6X24V 1000W EXCELSYS / Advanced Energy |
2,954 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 24V | 24V | 24V | 1000W | 24V | 24V | 85 ~ 264 VAC | 24V | 8.3 A | 3 A | 8.3 A | ITE (Commercial), Medical | 3 A | 8.3 A | 8.3 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-DAGGHA-P-A-DK00000ACDC CNVT 2X5V 2X24V 5V 24V 750W EXCELSYS / Advanced Energy |
2,965 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 48V | 5V | 24V | 750W | 24V | 24V | 85 ~ 264 VAC | 24V | 4.17 A | 3 A | 21 A | ITE (Commercial), Medical | 3 A | 3 A | 3 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
|
CX10S-DHGDGB-P-A-DK00000ACDC CNVT 12V 2X24V 48V 5V 2X24V EXCELSYS / Advanced Energy |
3,964 |
|
Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 48V | 5V | 24V | 920W | 24V | 24V | 85 ~ 264 VAC | 48V | 4.17 A | 4.17 A | 6 A | ITE (Commercial), Medical | 3 A | 3 A | 3 A | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |