Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Frame Type | Loading Side | Cavity Height | Cavity Width | Minimum Bend Radius | Outer Height | Outer Width | Length | Link Pitch | Features | Material | Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
E4-42-25-125-0Cble Carrier 2.52H 10.87W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 9.843" (250.00mm) | 4.920" (124.97mm) | 2.520" (64.01mm) | 10.866" (276.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-42-25-175-0Cble Carrier 2.52H 10.87W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 9.843" (250.00mm) | 6.890" (175.00mm) | 2.520" (64.01mm) | 10.866" (276.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-56-06-135-0Cble Carrier 3.31H 3.90W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-56 | Bulk | Active | Open | Inside and Outside Bend | 2.205" (56.00mm) | 2.559" (65.00mm) | 5.315" (135.00mm) | 3.307" (84.00mm) | 3.898" (99.00mm) | - | 3.580" (90.93mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-42-262-075-0Cble Carrier 2.52H 11.38W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 10.315" (262.00mm) | 2.953" (75.00mm) | 2.520" (64.01mm) | 11.378" (289.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-42-262-125-0Cble Carrier 2.52H 11.38W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 10.315" (262.00mm) | 4.920" (124.97mm) | 2.520" (64.01mm) | 11.378" (289.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-42-262-200-0Cble Carrier 2.52H 11.38W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 10.315" (262.00mm) | 7.874" (200.00mm) | 2.520" (64.01mm) | 11.378" (289.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-42-262-250-0Cble Carrier 2.52H 11.38W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 10.315" (262.00mm) | 9.840" (249.94mm) | 2.520" (64.01mm) | 11.378" (289.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-42-262-150-0Cble Carrier 2.52H 11.38W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-42 | Bulk | Active | Open | Inside and Outside Bend | 1.654" (42.00mm) | 10.315" (262.00mm) | 5.906" (150.00mm) | 2.520" (64.01mm) | 11.378" (289.00mm) | - | 2.640" (67.06mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-56-06-175-0Cble Carrier 3.31H 3.90W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-56 | Bulk | Active | Open | Inside and Outside Bend | 2.205" (56.00mm) | 2.559" (65.00mm) | 6.890" (175.00mm) | 3.307" (84.00mm) | 3.898" (99.00mm) | - | 3.580" (90.93mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E4-56-06-300-0Cble Carrier 3.31H 3.90W;1=1ft Igus |
200 |
|
![]() Datasheet |
E4-56 | Bulk | Active | Open | Inside and Outside Bend | 2.205" (56.00mm) | 2.559" (65.00mm) | 11.811" (300.00mm) | 3.307" (84.00mm) | 3.898" (99.00mm) | - | 3.580" (90.93mm) | - | Igumid G | -40°C ~ 120°C |