Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
DHAB S/113TRANSDUCER |
2,400 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 40A | 1 | Ratiometric, Voltage | 50mV/A | DC ~ 70Hz | ±0.5% | ±1.5% | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
DHAB S/101TRANSDUCER |
2,042 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
DHAB S/114TRANSDUCER |
4,014 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
DHAB S/133TRANSDUCER |
2,940 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 75A | 1 | Ratiometric, Voltage | 26.7mV/A | 1.1kHz | ±0.5% | ±2.5% | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
DHAB S/159TRANSDUCER |
3,660 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | 20mV/A | DC ~ 70Hz | ±0.5% | ±3.75% | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
DHAB S/138TRANSDUCER |
4,479 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A, -320A ~ 450A | 2 | Voltage | 40mV/A | DC ~ 1.1kHz | ±0.5% | - | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
DHAB S/143TRANSDUCER |
3,416 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 1.1kHz | ±0.5% | ±1.5% | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
DHAB S/158TRANSDUCER |
4,642 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A, -1000A ~ 500A | 2 | Voltage | 20mV/A | DC ~ 1.1kHz | ±0.5% | - | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
DHAB S/145TRANSDUCER |
4,960 |
|
![]() Datasheet |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | 40mV/A | DC ~ 1.1kHz | ±0.5% | ±1.5% | 4.75V ~ 5.25V | - | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
CSLA2CFISENSOR CURRENT HALL 125A AC/DC |
2,873 |
|
![]() Datasheet |
CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 125A | 1 | Ratiometric, Voltage | 19.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
![]() |
LT 308-S7/SP12TRANSDUCER |
3,488 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LT 208-S7/SP12TRANSDUCER |
3,822 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LT 58-S7TRANSDUCER |
3,646 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LT 108-S7/SP12TRANSDUCER |
4,762 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
CTSR 2-P/SP10TRANSDUCER |
4,874 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
L40S500D15JCURRENT SENSOR (500A; 15V) -40 1 |
2,079 |
|
![]() Datasheet |
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
L40S500D15MCURRENT SENSOR (500A; 15V) -40 1 |
2,776 |
|
![]() Datasheet |
L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 500A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LA 25-NP/SP14TRANSDUCER CURENT CLOSE LOOP .25 |
2,645 |
|
![]() Datasheet |
* | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
HTB 100-P/SP1TRANSDUCER |
2,896 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSDA1DCSENSOR CURRENT SWITCH 7.5A AC/DC |
4,545 |
|
![]() Datasheet |
CSDA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Current Switch | 7.5A | 1 | NPN | - | - | - | ±0.5% | 6V ~ 16V | 100µs | 12mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |