| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | For Measuring | Sensor Type | Number of Channels | Output | Sensitivity | Polarization | Frequency | Linearity | Current - Sensing | Accuracy | Voltage - Supply | Qualification | Response Time | Mounting Style | Grade | Current - Supply (Max) | Operating Temperature | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AI-P1ATRANSDUCER |
4,442 |
|
Datasheet |
AI | Module | Bulk | Active | AC | Rogowski Coil | 1 | Current | 22.5mV/kA | Unidirectional | 10Hz ~ 1.5kHz | ±1% | 5000A | ±0.5% | 16.8V ~ 31.2V | - | - | DIN Rail | - | 350mA | -25°C ~ 70°C | - |
|
CR4460-30SENSOR CURRENT XFMR 30A AC |
3,311 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 30A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 90mA | 0°C ~ 60°C | - |
|
CR4460-20SENSOR CURRENT XFMR 20A AC |
4,228 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 20A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 90mA | 0°C ~ 60°C | - |
|
CR4460-10SENSOR CURRENT XFMR 10A AC |
3,209 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 10A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 90mA | 0°C ~ 60°C | - |
|
CR4460-15SENSOR CURRENT XFMR 15A AC |
4,359 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 15A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 90mA | 0°C ~ 60°C | - |
|
CR4460-5SENSOR CURRENT XFMR 5A AC |
4,170 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 5A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 90mA | 0°C ~ 60°C | - |
|
CR4460-25SENSOR CURRENT XFMR 25A AC |
2,769 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 25A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 90mA | 0°C ~ 60°C | - |
|
LF 1005-S/SP13TRANSDUCER |
2,340 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 150kHz | ±0.1% | 1000A | ±0.4% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -40°C ~ 85°C | - |
|
LF 1005-S/SP1TRANSDUCER |
4,392 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 150kHz | ±0.1% | 500A | ±0.6% | ±12V ~ 18V | - | 1µs | Chassis Mount | - | - | -10°C ~ 70°C | - |
|
CR4260-0.5SENSOR CURRENT XFMR 0.5A AC |
3,938 |
|
Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 500mA | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | - | 0°C ~ 60°C | - |
|
CR4220S-100SENSOR CURRENT XFMR 100A AC |
4,516 |
|
Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 100A | ±0.5% | 24V | - | 250ms | DIN Rail | - | - | 0°C ~ 60°C | - |
|
ICD-A-300-CAN2-12CURRENT SENSOR - ISA-SCALE DC CO |
2,765 |
|
Datasheet |
ICD | Module | Tray | Active | DC | Shunt | 1 | - | - | Bidirectional | - | ±0.1% | 300A | ±0.8% | 5.5V ~ 26V | - | - | Chassis Mount | Automotive | 50mA | -40°C ~ 105°C | - |
|
CTSG0000SENSOR CURRENT SWITCH 250A AC |
4,280 |
|
Datasheet |
CTS | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 1 | SSR | - | Bidirectional | 6Hz ~ 100Hz | - | 250A | - | Self Powered | - | 120ms | Chassis Mount | - | 150mA | -50°C ~ 65°C | - |
|
SRCN-C290-410 CHANNELS AC CURRENT SENSOR RS |
2,103 |
|
- |
SRCN | Module | Bag | Active | AC/DC | Current Sensor | 10 | RS485 | - | Bidirectional | - | - | 50A | ±2.5% | 23.5V ~ 24.5V | - | - | DIN Rail | - | 60mA | 0°C ~ 65°C | - |
|
ENCORE (3A)TRANSDUCER CURRENT SENS SHUNT 3A |
4,678 |
|
Datasheet |
Encore | Module, Single Pass Through | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | 40kHz | - | 3A | ±0.2% | - | - | - | Free Hanging | - | - | -25°C ~ 70°C | - |
|
ARU-B100-D300/SP3SENSOR |
3,076 |
|
Datasheet |
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1 | Voltage | 0.1mV/A | Unidirectional | 346kHz | - | 1000A | ±0.5% | - | - | - | Chassis Mount | - | - | -40°C ~ 80°C | - |
|
LTC 500-TTRANSDUCER |
2,349 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 500A | ±0.6% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -40°C ~ 85°C | - |
|
LT 505-STRANSDUCER |
3,516 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Current Transducer | 1 | - | - | Bidirectional | DC ~ 150kHz | ±0.1% | 500A | ±0.6% | 15V ~ 24V | - | 1µs | Chassis Mount | - | 30mA | -10°C ~ 85°C | - |
|
LTC 600-SFC/SP14TRANSDUCER |
2,532 |
|
- |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 500A | ±1.6% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -40°C ~ 105°C | - |
|
CR4420S-40SENSOR CURRENT XFMR 40A AC |
3,116 |
|
Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 40A | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 45mA | 0°C ~ 60°C | - |