| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | For Measuring | Sensor Type | Number of Channels | Output | Sensitivity | Polarization | Frequency | Linearity | Current - Sensing | Accuracy | Voltage - Supply | Qualification | Response Time | Mounting Style | Grade | Current - Supply (Max) | Operating Temperature | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LF 2005-S/SP1TRANSDUCER |
3,159 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 150kHz | ±0.1% | 2000A | ±0.3% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -40°C ~ 85°C | - |
|
LF 2005-S/SP21TRANSDUCER |
4,382 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 2000A | ±0.4% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -40°C ~ 85°C | - |
|
LV 100-300/SP9SENSORS |
4,429 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 100-T/SP30TRANSDUCER |
4,000 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 2005-S/SP19TRANSDUCER |
4,713 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LT 1005-T/SP13TRANSDUCER |
3,565 |
|
- |
LT | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 150kHz | ±0.1% | 1000A | ±0.4% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -10°C ~ 85°C | - |
|
CR4150-0.5SENSOR CURRENT XFMR 0.5A AC |
4,685 |
|
Datasheet |
CR4100 | Module, Dual Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 2 | Ratiometric, 0V ~ 5V | - | Bidirectional | 20Hz ~ 5kHz | - | 500mA | ±0.5% | 24V | - | 250ms | DIN Rail, Panel | - | 75mA | 0°C ~ 60°C | - |
|
CV 3-1000/SP3TRANSDUCER |
4,730 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ISOBLOCK I-ST-1C (5A 10V)SHUNT BASED CURRENT SENSOR |
4,594 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 5A | ±0.2% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |
|
1136513SENSOR CURRENT HALL 55A AC/DC |
3,778 |
|
Datasheet |
- | Module | Bulk | Active | AC/DC | Current Transducer | 1 | Analog Voltage | - | Bidirectional | DC, 10Hz ~ 1kHz | - | 50A | - | 9.6V ~ 30V | - | 200ms | DIN Rail | - | - | -40°C ~ 60°C | - |
|
1698164SENSOR CURRENT HALL 11A AC/DC |
3,109 |
|
Datasheet |
- | Module | Bulk | Active | AC/DC | Current Transducer | 1 | Analog Voltage | - | Bidirectional | DC, 10Hz ~ 1kHz | - | 1A, 5A, 10A (Selectable) | - | 9.6V ~ 30V | - | 200ms | DIN Rail | - | - | -40°C ~ 60°C | - |
|
HAZ 10000-SBITRANSDUCER |
2,211 |
|
Datasheet |
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Current | - | Bidirectional | DC ~ 3kHz | ±0.5% | 10000A | ±1% | ±15V | - | 10µs | Chassis Mount | - | 50mA | -25°C ~ 85°C | - |
|
HAZ 10000-SBI/SP1TRANSDUCER |
2,731 |
|
Datasheet |
HAZ | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Current | - | Bidirectional | DC ~ 3kHz | ±0.5% | 10000A | ±1% | ±15V | - | 10µs | Chassis Mount | - | 50mA | -25°C ~ 85°C | - |
|
LT 100-T/SP43TRANSDUCER |
2,022 |
|
- |
LT | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 150kHz | ±0.1% | 100A | ±0.5% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -25°C ~ 70°C | - |
|
ISOBLOCK I-ST-1C (20MA 5V 0.1%)SHUNT BASED CURRENT SENSOR |
2,917 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 20mA | ±0.1% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |
|
ISOBLOCK I-ST-1C (1MA 10V 0.1%)SHUNT BASED CURRENT SENSOR |
3,517 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 1mA | ±0.1% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |
|
ISOBLOCK I-ST-1C (20A 5V 0.1%)SHUNT BASED CURRENT SENSOR |
3,836 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 20A | ±0.1% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |
|
ISOBLOCK I-ST-1C (2MA 5V 0.1%)SHUNT BASED CURRENT SENSOR |
3,627 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 2mA | ±0.1% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |
|
ISOBLOCK I-ST-1C (300MA 5V 0.1%)SHUNT BASED CURRENT SENSOR |
4,626 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 300mA | ±0.1% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |
|
ISOBLOCK I-ST-1C (30A 5V 0.1%)SHUNT BASED CURRENT SENSOR |
4,251 |
|
Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1 | Open Collector | - | - | - | - | 30A | ±0.1% | 9V ~ 28VDC | - | 5µs | DIN Rail | - | - | -25°C ~ 65°C | - |