Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
L32P050S05FSSENSOR CURRENT HALL 50A AC/DC Tamura |
0 |
|
![]() Datasheet |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
![]() |
L31S600S05FSSENSOR CURRENT HALL 600A AC/DC Tamura |
0 |
|
![]() Datasheet |
L31SXXXS05S | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
F01P015S05SENSOR CURRENT FLUX GATE 15A AC Tamura |
0 |
|
![]() Datasheet |
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±1% | ±1.9% | 5V | 0.3µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
F02P015S05SENSOR CURRENT FLUX GATE 15A AC Tamura |
0 |
|
![]() Datasheet |
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.67mV/A | 300kHz | ±1% | ±1.2% | 5V | 0.3µs | 30mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
![]() |
L32P100S05FSSENSOR CURRENT HALL 100A AC/DC Tamura |
0 |
|
![]() Datasheet |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
![]() |
L03S050D15SENSOR CURRENT HALL 50A AC/DC Tamura |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
![]() |
L32P150S05FSSENSOR CURRENT HALL 150A AC/DC Tamura |
0 |
|
![]() Datasheet |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±0.5% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
![]() |
L03S100D15SENSOR CURRENT HALL 100A AC/DC Tamura |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 12mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
F01P025S05SENSOR CURRENT FLUX GATE 25A AC Tamura |
0 |
|
![]() Datasheet |
F01P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1.8% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
F02P025S05SENSOR CURRENT FLUX GATE 25A AC Tamura |
0 |
|
![]() Datasheet |
F02P | Module | Bulk | Obsolete | AC | Flux Gate, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | 300kHz | ±1% | ±1% | 5V | 0.3µs | 35mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |