Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
80AFEFUSE 80A 690V TYPE T (10) |
4,517 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
HVU-1FUSE CARTRIDGE 1A 5KVAC |
4,527 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 1A | 5 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.810" Dia x 4.996" L (20.57mm x 126.90mm) | - | - |
![]() |
HVU-5FUSE CARTRIDGE 5A 5KVAC |
4,083 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 5A | 5 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.810" Dia x 4.996" L (20.57mm x 126.90mm) | - | - |
![]() |
30H07CFUSE CARTRIDGE 30A 600VAC/250VDC |
4,835 |
|
![]() Datasheet |
- | Cylindrical, Blade Terminal (Alternating) | Bulk | Active | Bolt Mount | Cartridge | 30A | 600 VAC | 250 VDC | - | Electrical, Industrial | - | - | CE, CSA | - | 200kA | 0.551" Dia x 1.378" L (14.00mm x 35.00mm) | - | - |
![]() |
HVU-2FUSE CARTRIDGE 2A 5KVAC |
3,926 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 2A | 5 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.810" Dia x 4.996" L (20.57mm x 126.90mm) | - | - |
![]() |
HVU-3FUSE CARTRIDGE 3A 5KVAC |
3,123 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 3A | 5 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.810" Dia x 4.996" L (20.57mm x 126.90mm) | - | - |
![]() |
CGL-10FUSE CARTRIDGE 10A 600VAC/250VDC |
4,838 |
|
![]() Datasheet |
Tron® CGL | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 10A | 600 VAC | 250 VDC | - | Motor Protection, Transformer Protection | - | C | CE, CSA | - | - | 0.813" Dia x 2.000" L (20.64mm x 50.80mm) | - | - |
![]() |
HVU-4FUSE CARTRIDGE 4A 5KVAC |
3,818 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 4A | 5 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.810" Dia x 4.996" L (20.57mm x 126.90mm) | - | - |
![]() |
CGL-15FUSE CARTRIDGE 15A 600VAC/250VDC |
2,579 |
|
![]() Datasheet |
Tron® CGL | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 15A | 600 VAC | 250 VDC | - | Motor Protection, Transformer Protection | - | C | CE, CSA | - | - | 0.813" Dia x 2.000" L (20.64mm x 50.80mm) | - | - |
![]() |
004721105FUSE 16A 690VAC 550VDC |
2,440 |
|
- |
- | - | Bulk | Active | - | - | 16A | 690 VAC | 550 VDC | - | - | - | - | - | - | - | - | - | - |
![]() |
ANN-150BUSS AIRCRAFT LIMITER |
2,464 |
|
![]() Datasheet |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
TCP32FUSE 32A 660V AC / 460V DC INDUS |
2,999 |
|
![]() Datasheet |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
HVU-1/2FUSE CARTRIDGE 500MA 5KVAC |
2,606 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 500mA | 5 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.810" Dia x 4.996" L (20.57mm x 126.90mm) | - | - |
![]() |
HVA-10FUSE CARTRIDGE 10A 1KVAC |
2,031 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 10A | 1 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.410" Dia x 2.996" L (10.41mm x 76.10mm) | - | - |
![]() |
HVA-3FUSE CARTRIDGE 3A 1KVAC |
3,341 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 3A | 1 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.410" Dia x 2.996" L (10.41mm x 76.10mm) | - | - |
![]() |
HVA-4FUSE CARTRIDGE 4A 1KVAC |
2,610 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 4A | 1 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.410" Dia x 2.996" L (10.41mm x 76.10mm) | - | - |
![]() |
HVA-6FUSE CARTRIDGE 6A 1KVAC |
4,026 |
|
![]() Datasheet |
HV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 6A | 1 kVAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | 0.410" Dia x 2.996" L (10.41mm x 76.10mm) | - | - |
![]() |
ANN-300BUSS AIRCRAFT LIMITER |
4,300 |
|
![]() Datasheet |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
CIA30FUSE 30A 660V AC C.S.A. CANADIAN |
4,421 |
|
- |
- | - | - | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
100NHG0BFUSE SQUARE 100A 500VAC RECT |
4,203 |
|
![]() Datasheet |
- | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 100A | 500 VAC | - | - | Electrical, Industrial | Indicating | NH | CE, VDE | - | 120kA | 2.677" L x 1.181" W x 1.969" H (68.00mm x 30.00mm x 50.00mm) | - | - |