Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Voltage - Rated | Size / Dimension | Width | Air Flow | Static Pressure | Bearing Type | Fan Type | Features | Noise | Power (Watts) | RPM | Termination | Ingress Protection | Operating Temperature | Approval Agency | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
9LB1412S501FAN AXIAL 140X51MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140L | Box | Obsolete | 12VDC | Square - 140mm L x 140mm H | 51.00mm | 286.2 CFM (8.01m³/min) | 0.960 in H2O (239.1 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 57.0dB(A) | 32.4 W | 4200 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.3 lbs (610.0 g) |
|
9LB1424M501FAN AXIAL 140X51MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140L | Box | Obsolete | 24VDC | Square - 140mm L x 140mm H | 51.00mm | 138.0 CFM (3.86m³/min) | 0.250 in H2O (62.3 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 39.0dB(A) | 5.28 W | 2050 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.3 lbs (610.0 g) |
|
9LB1448H501FAN AXIAL 140X51MM 48VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140L | Box | Obsolete | 48VDC | Square - 140mm L x 140mm H | 51.00mm | 208.5 CFM (5.84m³/min) | 0.522 in H2O (130.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 49.0dB(A) | 12.96 W | 3100 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.3 lbs (610.0 g) |
|
9LB1448S501FAN AXIAL 140X51MM 48VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140L | Box | Obsolete | 48VDC | Square - 140mm L x 140mm H | 51.00mm | 286.2 CFM (8.01m³/min) | 0.964 in H2O (240.0 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 57.0dB(A) | 34.08 W | 4200 RPM | 3 Wire Leads | - | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.3 lbs (610.0 g) |
![]() |
9WB1412H501FAN AXIAL 140X51MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140W | Box | Obsolete | 12VDC | Square - 140mm L x 140mm H | 51.00mm | 208.5 CFM (5.84m³/min) | 0.520 in H2O (129.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 49.0dB(A) | 15 W | 3100 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.543 lb (700.0 g) |
![]() |
9WB1412H502FAN AXIAL 140X51MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140W | Box | Obsolete | 12VDC | Square - 140mm L x 140mm H | 51.00mm | 208.5 CFM (5.84m³/min) | 0.520 in H2O (129.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 49.0dB(A) | 15 W | 3100 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.543 lb (700.0 g) |
![]() |
9WB1424H501FAN AXIAL 140X51MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140W | Box | Obsolete | 24VDC | Square - 140mm L x 140mm H | 51.00mm | 208.5 CFM (5.84m³/min) | 0.520 in H2O (129.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection, Speed Sensor (Tach) | 49.0dB(A) | 14.4 W | 3100 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.543 lb (700.0 g) |
![]() |
9WB1424H502FAN AXIAL 140X51MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 140W | Box | Obsolete | 24VDC | Square - 140mm L x 140mm H | 51.00mm | 208.5 CFM (5.84m³/min) | 0.520 in H2O (129.5 Pa) | Ball | Tubeaxial | Locked Rotor Protection | 49.0dB(A) | 14.4 W | 3100 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 1.543 lb (700.0 g) |
![]() |
9WP0612G4011FAN AXIAL 60X25MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 60W | Box | Obsolete | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 27.5 CFM (0.770m³/min) | 0.351 in H2O (87.3 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 39.0dB(A) | 2.52 W | 5600 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.243 lb (110.22 g) |
|
9WP0612H402FAN AXIAL 60X25MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 60W | Box | Obsolete | 12VDC | Square - 60mm L x 60mm H | 25.00mm | 18.7 CFM (0.524m³/min) | 0.161 in H2O (40.2 Pa) | Ball | Tubeaxial | - | 28.0dB(A) | 1.32 W | 3800 RPM | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | 0.243 lb (110.22 g) |
|
9WP0624H402FAN AXIAL 60X25MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 60W | Box | Obsolete | 24VDC | Square - 60mm L x 60mm H | 25.00mm | 18.7 CFM (0.524m³/min) | 0.161 in H2O (40.2 Pa) | Ball | Tubeaxial | - | 28.0dB(A) | 1.44 W | 3800 RPM | 2 Wire Leads | IP55 - Dust Protected, Water Resistant | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | 0.243 lb (110.22 g) |
![]() |
9WP0812G402FAN AXIAL 80X25MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 80W | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 53.0 CFM (1.48m³/min) | 0.323 in H2O (80.4 Pa) | Ball | Tubeaxial | - | 40.0dB(A) | 4.56 W | 4500 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.287 lb (130.18 g) |
![]() |
9WP0812P4G01FAN AXIAL 80X25MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 80W | Box | Obsolete | 12VDC | Square - 80mm L x 80mm H | 25.00mm | 53.0 CFM (1.48m³/min) | 0.323 in H2O (80.4 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 40.0dB(A) | 4.56 W | 4500 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.287 lb (130.18 g) |
![]() |
9WP0824H402FAN AXIAL 80X25MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 80W | Box | Obsolete | 24VDC | Square - 80mm L x 80mm H | 25.00mm | 36.3 CFM (1.02m³/min) | 0.142 in H2O (35.4 Pa) | Ball | Tubeaxial | - | 29.0dB(A) | 1.68 W | 2900 RPM | 2 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.287 lb (130.18 g) |
![]() |
9WP0924B401FAN AXIAL 92X25MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 92W | Box | Obsolete | 24VDC | Square - 92mm L x 92mm H | 25.00mm | 31.8 CFM (0.890m³/min) | 0.072 in H2O (17.9 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 23.0dB(A) | 1.2 W | 2000 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | 14 ~ 158°F (-10 ~ 70°C) | CSA, TUV, UL | 0.265 lb (120.2 g) |
![]() |
9WP0924H401FAN AXIAL 92X25MM 24VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 92W | Box | Obsolete | 24VDC | Square - 92mm L x 92mm H | 25.00mm | 51.2 CFM (1.43m³/min) | 0.177 in H2O (44.1 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 33.0dB(A) | 2.4 W | 3150 RPM | 3 Wire Leads | IP68 - Dust Tight, Waterproof | -4 ~ 158°F (-20 ~ 70°C) | CSA, TUV, UL | 0.265 lb (120.2 g) |
![]() |
9WS1212H101FAN AXIAL 119X38MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 120WS | Box | Obsolete | 12VDC | Square - 119mm L x 119mm H | 38.00mm | 102.4 CFM (2.87m³/min) | 0.272 in H2O (67.7 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 39.0dB(A) | 5.64 W | 2600 RPM | 3 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.573 lb (259.91 g) |
![]() |
9WS1212H1011FAN AXIAL 119X38MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 120WS | Box | Obsolete | 12VDC | Square - 119mm L x 119mm H | 38.00mm | 102.4 CFM (2.87m³/min) | 0.272 in H2O (67.7 Pa) | Ball | Tubeaxial | Speed Sensor (Tach) | 39.0dB(A) | 5.64 W | 2600 RPM | 3 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.573 lb (259.91 g) |
![]() |
9WS1212H102FAN AXIAL 119X38MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 120WS | Box | Obsolete | 12VDC | Square - 119mm L x 119mm H | 38.00mm | 102.4 CFM (2.87m³/min) | 0.272 in H2O (67.7 Pa) | Ball | Tubeaxial | - | 39.0dB(A) | 5.64 W | 2600 RPM | 2 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.573 lb (259.91 g) |
![]() |
9WS1212H1021FAN AXIAL 119X38MM 12VDC WIRE |
0 |
|
![]() Datasheet |
San Ace 120WS | Box | Obsolete | 12VDC | Square - 119mm L x 119mm H | 38.00mm | 102.4 CFM (2.87m³/min) | 0.272 in H2O (67.7 Pa) | Ball | Tubeaxial | - | 39.0dB(A) | 5.64 W | 2600 RPM | 2 Wire Leads | IP54 - Dust Protected, Water Resistant | -4 ~ 140°F (-20 ~ 60°C) | CSA, TUV, UL | 0.573 lb (259.91 g) |