Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Sensor Type | Humidity Range | Output Type | Output | Accuracy | Response Time | Sensitivity | Voltage - Supply | Mounting Type | Operating Temperature | Grade | Qualification | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
HS3004-ML1IC MODULE |
0 |
|
- |
HS300x-ML1 | 4-SIP Module | Bulk | Obsolete | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±3.5% RH | 6 s | - | 2.3V ~ 5.5V | Through Hole | -40°C ~ 125°C | - | - | - |
![]() |
HS3002-ML1IC MODULE |
0 |
|
- |
- | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
HS3102-ML1IC MODULE |
0 |
|
- |
HS310x-ML1 | 4-SIP Module | Bulk | Obsolete | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±1.8% RH | 6 s | - | 2.3V ~ 5.5V | Through Hole | -40°C ~ 125°C | - | - | - |
![]() |
HS3104-ML1IC MODULE |
0 |
|
- |
HS310x-ML1 | 4-SIP Module | Bulk | Obsolete | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±3.5% RH | 6 s | - | 2.3V ~ 5.5V | Through Hole | -40°C ~ 125°C | - | - | - |
![]() |
HU-224-3-MAHumidity Sensor, Duct Mount, 3pc |
0 |
|
- |
HU-224 | - | Retail Package | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
OFT420-CSENSOR HUMI/TEMP ANALOG |
0 |
|
![]() Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
![]() |
OHT20-CSENSOR HUMI/TEMP USB |
0 |
|
![]() Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Digital | - | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 5V | Cable | -25°C ~ 70°C | - | - | Radial |
![]() |
OHT20-ASENSOR HUMI/TEMP USB |
0 |
|
![]() Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Digital | - | ±1.5% RH | 3 s | 0.01°C, 0.01% RH | 5V | Cable | -25°C ~ 70°C | - | - | Radial |
![]() |
OFT010-BSENSOR HUMI/TEMP ANALOG |
0 |
|
![]() Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog | 0V ~ 10V | ±2% | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
![]() |
OFT025-CSENSOR HUMI/TEMP ANALOG |
0 |
|
![]() Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog | 0V ~ 2.5V | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
![]() |
OFT005-CSENSOR HUMI/TEMP ANALOG |
0 |
|
![]() Datasheet |
- | Radial | Retail Package | Active | Humidity, Temperature | 0 ~ 100% RH | Analog | 0V ~ 5V | ±3.5% RH | 3 s | 0.01°C, 0.01% RH | 21.6V ~ 26.4V | Cable | -25°C ~ 70°C | - | - | Radial |
![]() |
26312factory calibrated |
6 |
|
- |
- | 4-SIP Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | - | - | ±5% RH | - | - | 3.5V ~ 5.5V | Through Hole | -40°C ~ 80°C | - | - | - |
![]() |
NZH-101UHumidstat, Room, Internal Setpoi |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | SPDT | - | ±3% RH | 72 s | - | - | Chassis Mount | 0°C ~ 60°C | - | - | - |
![]() |
A/RH5-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH5-RRelative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | - |
![]() |
A/RH5-AN-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH5-CP-RRelative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH5-AN-RRelative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH5-CP-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH5-DRelative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±5% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |