Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Trip Status | Trip Range | Delay Time | Voltage - Supply | Output Type | Circuit | Contact Rating @ Voltage | Mounting Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PBD-440-ALEPBD SERIES 3-PHASE SEQUENCE & VO |
5 |
|
![]() Datasheet |
PBD | Box | Active | Voltage Sensing AC, Phase Sequence | Energized High/Low | 390 ~ 540V AC | 0.1 Sec ~ 30 Sec | 440VAC | Relay | DPDT (2 Form C) | 10A @ 240VAC | Chassis Mount |
![]() |
PBD-230-ALEPBD SERIES 3-PHASE SEQUENCE & VO |
4 |
|
![]() Datasheet |
PBD | Box | Active | Voltage Sensing AC, Phase Sequence | Energized High/Low | 185 ~ 265V AC | 0.1 Sec ~ 30 Sec | 230VAC | Relay | DPDT (2 Form C) | 10A @ 240VAC | Chassis Mount |
![]() |
2456840000ACT20P-UI-2RCO-DC-P |
2 |
|
![]() Datasheet |
ACT20P | Box | Active | Process Sensing | Energized High/Low | - | No Delay | 9 ~ 60VDC | Relay | DPDT (2 Form C) | 6A @ 250VAC/110VDC | DIN Rail |
![]() |
SLM-440-ASESLM SERIES MICROPROCESSOR-BASED |
3 |
|
![]() Datasheet |
SLM | Box | Active | Frequency, Phase Loss, Phase Sequence, Voltage Sensing AC | Energized High/Low | 440 ~ 490V AC | 1.5 Sec ~ 5 Min | 440VAC | Relay | DPDT (2 Form C) | 3A @ 600VAC | Chassis Mount |
![]() |
1238910000ACT20P-UI-2RCO-AC-S |
3 |
|
![]() Datasheet |
ACT20P | Box | Active | Process Sensing | Energized High/Low | - | No Delay | 90 ~ 264VAC | Relay | DPDT (2 Form C) | 6A @ 250VAC/110VDC | DIN Rail |
![]() |
LWRS440APHASE CTRL RLY, 11-PIN, 3X440VAC |
7 |
|
![]() Datasheet |
WRS | Box | Obsolete | Phase Loss, Phase Sequence | Energized High | - | No Delay | 440VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
![]() |
264VOLTAGE MONITOR |
2 |
|
![]() Datasheet |
200 | Box | Active | Voltage Sensing DC | - | 6 ~ 30VDC | 0 ~ 10 Sec | 6 ~ 30VDC | Relay | SPDT (1 Form C) | 16A @ 250VAC/24VDC | DIN Rail |
![]() |
235MONITORING VOLTAGE MONITOR |
3 |
|
![]() Datasheet |
200 | Box | Active | Voltage Sensing AC | - | 48 ~ 276VAC | 0 ~ 10 Sec | 48 ~ 276VAC | Relay | SPDT (1 Form C) | 16A @ 250VAC/24VDC | DIN Rail |
|
PWRA440ACONTROL RELAY PHASE 3X440VAC |
0 |
|
![]() Datasheet |
WRA | Tray | Obsolete | Phase Loss, Phase Sequence | Energized High | - | No Delay | 440VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
![]() |
LWRA440ACONTROL RELAY PHASE 3X440VAC |
5 |
|
![]() Datasheet |
WRA | Box | Obsolete | Phase Loss, Phase Sequence | Energized High | - | No Delay | 440VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
|
DWRS220ACONTROL RELAY PHASE 3X220VAC DIN |
0 |
|
![]() Datasheet |
WRS | Tray | Obsolete | Phase Loss, Phase Sequence | Energized High | - | No Delay | 220VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | DIN Rail |
![]() |
DWRS440APHASE CTRL RLY, DIN RAIL, 3X440V |
0 |
|
![]() Datasheet |
WRS | Tray | Obsolete | Phase Loss, Phase Sequence | Energized High | - | No Delay | 440VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | DIN Rail |
![]() |
PSR24DCONTROL RELAY UNDER VOLT 24VDC |
10 |
|
- |
SR | Tray | Obsolete | Voltage Sensing AC/DC | Energized High | 48 ~ 220V AC, 12 ~ 24V DC | No Delay | 24VDC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
|
PSR220ACONTROL RELAY UNDER VOLT 220VAC |
0 |
|
- |
SR | Bulk | Obsolete | Voltage Sensing AC/DC | Energized High | 48 ~ 220V AC, 12 ~ 24V DC | No Delay | 220VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
![]() |
PWRS440ACONTROL RELAY PHASE 3X440VAC |
0 |
|
![]() Datasheet |
WRS | Bulk | Obsolete | Phase Loss, Phase Sequence | Energized High | - | No Delay | 440VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
|
DSR24DCONTROL RELAY UNDER VOLT 24VDC |
0 |
|
- |
SR | Box | Obsolete | Voltage Sensing AC/DC | Energized High | 48 ~ 220V AC, 12 ~ 24V DC | No Delay | 24VDC | Relay | SPDT (1 Form C) | 10A @ 250VAC | DIN Rail |
![]() |
DIRT24DICONTROL RELAY CURRENT 24VDC DIN |
0 |
|
![]() Datasheet |
IR.T | Bulk | Obsolete | Current Sensing AC | Energized High | 3.5mA ~ 7.07A | 0.1 Sec ~ 10 Sec | 24VDC | - | SPDT (1 Form C) | 10A @ 250VAC | DIN Rail |
![]() |
LIRT220ACONTROL RELAY CURRENT 220VAC |
0 |
|
![]() Datasheet |
IR.T | Bulk | Obsolete | Current Sensing AC | Energized High | 0.035 ~ 7.07A AC, 0.05 ~ 10A AC | 0.1 Sec ~ 10 Sec | 220VAC | Relay | SPDT (1 Form C) | 10A @ 250VAC | Socketable |
![]() |
84872024CONTROL RELAY VOLT 230VAC .2-60V |
0 |
|
![]() Datasheet |
C-Lynx | Bulk | Obsolete | Voltage Sensing AC/DC | Energized High/Low | 0.2 ~ 60V AC/DC | 0.1 Sec ~ 3 Sec | 230VAC | Relay | SPDT (1 Form C) | 8A @ 250VAC | DIN Rail |
|
84871020CONTROL RLY CURRNT 24VDC 2-500MA |
0 |
|
![]() Datasheet |
EIL | Bulk | Obsolete | Current Sensing AC/DC | Energized High | 2 ~ 500mA AC/DC | 0.1 Sec ~ 3 Sec | 24VDC | Relay | SPDT (1 Form C) | - | DIN Rail |