Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Trip Status | Trip Range | Delay Time | Voltage - Supply | Output Type | Circuit | Contact Rating @ Voltage | Mounting Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SAO-R1NSENSOR CURRENT 100/110/120VAC |
1 |
|
![]() Datasheet |
SAO | Bulk | Active | Current Sensing AC | - | - | No Delay | 100 ~ 120VAC | Relay | SPDT (1 Form C) | 3A @ 240VAC | Socketable |
![]() |
11027405EUW-C18 (MEASURING AND MONITORIN |
0 |
|
- |
- | Bulk | Active | Voltage Sensing AC | Energized High/Low | 1 ~ 300V AC/DC | 0.1 Sec ~ 9.9 Sec | 230VAC | Relay | DPDT (2 Form C) | 8A @ 250VAC | DIN Rail |
![]() |
CP51151-PHASE CENTER PIVOT PUMP CONT |
0 |
|
![]() Datasheet |
CP5 | Bulk | Obsolete | Current Sensing AC | Energized Low | 0 ~ 5A DC | 0 ~ 10 Min | 115VAC | Relay | SPDT (1 Form C) | 5A @ 240VAC | Chassis Mount |
![]() |
K8AB-AS1 24VAC/DCREL AC/DC CUR SENS 24VAC/DC DIN |
0 |
|
- |
K8AB-AS | Bulk | Obsolete | Current Sensing AC/DC | - | 2 ~ 500mA AC/DC | 0.1 Sec ~ 30 Sec | 24VAC/DC | Relay | SPDT (1 Form C) | 6A @ 250VAC | DIN Rail |
![]() |
K8AB-AS3 24VAC/DCREL AC CUR SENS 24VAC/DC DIN |
0 |
|
- |
K8AB-AS | Bulk | Obsolete | Current Sensing AC | - | 10 ~ 200A AC | 0.1 Sec ~ 30 Sec | 24VAC/DC | Relay | SPDT (1 Form C) | 6A @ 250VAC | DIN Rail |
![]() |
K8AB-VW2 100/115VACREL AC/DC VOLT SENS 100-115VAC |
0 |
|
![]() Datasheet |
K8AB-VW | Bulk | Obsolete | Voltage Sensing AC/DC | - | 1 ~ 150V AC/DC | 0.1 Sec ~ 30 Sec | 100 ~ 115VAC | Relay | SPDT (1 Form C) x 2 | 6A @ 250VAC | DIN Rail |
![]() |
K8AB-VW3 100/115VACREL AC/DC VOLT SENS 100-115VAC |
0 |
|
![]() Datasheet |
K8AB-VW | Bulk | Obsolete | Voltage Sensing AC/DC | - | 20 ~ 600V AC/DC | 0.1 Sec ~ 30 Sec | 100 ~ 115VAC | Relay | SPDT (1 Form C) x 2 | 6A @ 250VAC | DIN Rail |
![]() |
201-100-DPDT3-PH 11-PIN PLULG-IN VM / 95 - |
0 |
|
![]() Datasheet |
201-XXX-DPDT | Bulk | Active | Voltage Sensing AC | Energized Low | 95 ~ 120V AC | Fixed, 2 Sec, 4 Sec | 95 ~ 120VAC | Relay | DPDT (2 Form C) | 10A @ 240VAC | Socketable |
![]() |
201-100-SP-DPDT1-PH 8-PIN PLUG-IN VM / 95 - |
0 |
|
![]() Datasheet |
201-XXX-SP | Bulk | Active | Voltage Sensing AC | Energized Low | 95 ~ 120V AC | Fixed, 4 Sec | 95 ~ 120VAC | Relay | SPDT (1 Form C) | 10A @ 240VAC | Socketable |
![]() |
DTA01C115115 VAC THERMISTOR RELAY |
0 |
|
![]() Datasheet |
DTA01 | Box | Obsolete | Temperature Monitoring | Energized High | - | - | 115VAC | Relay | SPST-NO (1 Form A) | 8A @ 250VAC | DIN Rail |
![]() |
DTA01C230230 VAC THERMISTOR RELAY |
0 |
|
![]() Datasheet |
DTA01 | Box | Obsolete | Temperature Monitoring | Energized High | - | - | 230VAC | Relay | SPST-NO (1 Form A) | 8A @ 250VAC | DIN Rail |
![]() |
3UG46141BR280AA3DIGITAL MONITORING RELAY |
0 |
|
![]() Datasheet |
SIRIUS | Box | Active | Voltage Asymmetry, Voltage Sensing AC, Phase Loss, Phase Sequence | - | 160 ~ 690V AC | 0.1 Sec ~ 20 Sec | 160 ~ 690VAC | Relay | DPDT (2 Form C) | 3A @ 400VAC | DIN Rail |
![]() |
UOA-24-ALASINGLE PHASE UNDER VOLTAGE MONIT |
0 |
|
![]() Datasheet |
UOA | Box | Discontinued at Digi-Key | Voltage Sensing AC | Energized High/Low | 19 ~ 29V AC | 0.05 Sec ~ 0.5 Sec | 24VAC | Relay | DPDT (2 Form C) | 5A @ 240VAC | Socketable |
![]() |
201-200-DPDT3-PH 11-PIN PLUG-IN VM / 90 - |
0 |
|
![]() Datasheet |
201-XXX-DPDT | Bulk | Active | Voltage Sensing AC | Energized Low | 190 ~ 240V AC | Fixed, 2 Sec, 4 Sec | 190 ~ 240VAC | Relay | DPDT (2 Form C) | 10A @ 240VAC | Socketable |
![]() |
SCR9LRELAY TIME DELAY LED LAMP ALARM |
0 |
|
![]() Datasheet |
- | Bulk | Active | Current Sensing AC | Energized High/Low | 0.15A ~ 8A AC | Fixed, 10 Sec | 120 ~ 230VAC | Relay | SPDT (1 Form C) | 10A @ 240VAC/30VDC | Chassis Mount |
![]() |
460-575-143-PHASE VOLT.MONITOR/ 575V/ 1 |
0 |
|
![]() Datasheet |
460 | Bulk | Active | Voltage Asymmetry, Voltage Sensing AC, Phase Loss | Energized High/Low | 475 ~ 600V AC | Fixed, 2 Sec, 4 Sec | 190 ~ 480VAC | Relay | - | 10A @ 240VAC | DIN Rail |
![]() |
DIB71CB23500MACUR LVL RLY OVER/UNDER 10-500MA |
0 |
|
![]() Datasheet |
DIB71 | Box | Active | Current Sensing AC/DC | Energized High/Low | 10 ~ 500mA AC/DC | 0.1 Sec ~ 30 Sec | 115 ~ 230VAC | Relay | SPDT (1 Form C) | 5A @ 250VAC | DIN Rail |
![]() |
DIB71CB235MACURR LVL RLY OVER/UNDER 0.1-5MA |
0 |
|
![]() Datasheet |
DIB71 | Box | Active | Current Sensing AC/DC | Energized High/Low | 0.1 ~ 5mA AC/DC | 0.1 Sec ~ 30 Sec | 115 ~ 230VAC | Relay | SPDT (1 Form C) | 5A @ 250VAC | DIN Rail |
![]() |
DPA03CM48RLY 3PH SEQ/PASE LOSS |
0 |
|
![]() Datasheet |
DPA03 | Box | Active | Phase Loss, Phase Sequence | Energized Low | 320 ~ 480V AC | - | 380 ~ 480VAC | Relay | SPDT (1 Form C) | 8A @ 250VAC | DIN Rail |
![]() |
DUB71CB23500VRLY LVL OVER/UNDER 2-500 VAC/DC |
0 |
|
![]() Datasheet |
DUB71 | Box | Active | Voltage Sensing AC/DC | Energized High/Low | 2 ~ 500V AC/DC | 0.1 Sec ~ 30 Sec | 115 ~ 230VAC | Relay | SPDT (1 Form C) | 5A @ 250VAC | DIN Rail |