Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Function | Actuator Type | Operating Pressure | Orifice Diameter | Fluid Type | Connection Method | For Use With/Related Products | Mounting Type | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VSNC-F-P53E-MD-G14-F8SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSNC | Bulk | Active | Solenoid Valve | 5/3 | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air | Threaded G1/4" | Solenoid Valve | Chassis Mount | - |
![]() |
VSNC-F-P53U-MD-G14-F8SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSNC | Bulk | Active | Solenoid Valve | 5/3 | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air | Threaded G1/4" | Solenoid Valve | Chassis Mount | - |
![]() |
VSNC-F-P53U-MD-N14-F8SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSNC | Bulk | Active | Solenoid Valve | 5/3 | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air | Threaded 1/4" NPT | Solenoid Valve | Chassis Mount | - |
![]() |
VSNC-F-P53C-MD-N14-F8SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSNC | Bulk | Active | Solenoid Valve | 5/3 Normally Closed | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air | Threaded 1/4" NPT | Solenoid Valve | Chassis Mount | - |
![]() |
VSNC-F-P53C-MD-G14-F8SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSNC | Bulk | Active | Solenoid Valve | 5/3 Normally Closed | - | 44 ~ 145 PSI (3 ~ 10 bar) | - | Air | Threaded G1/4" | Solenoid Valve | Chassis Mount | - |
![]() |
VSVA-B-T32C-AH-A2-1C1SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSVA | Bulk | Active | Solenoid Valve | 2 x 3/2 Normally Closed | - | 29 ~ 145 PSI (2 ~ 10 bar) | - | Air | Threaded G1/8" | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-T32U-AH-A2-1C1SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSVA | Bulk | Active | Solenoid Valve | 2 x 3/2 Normally Open | - | 29 ~ 145 PSI (2 ~ 10 bar) | - | Air | Threaded G1/8" | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VSVA-B-T32H-AH-A2-1C1SOLENOID VALVE |
0 |
|
![]() Datasheet |
VSVA | Bulk | Active | Solenoid Valve | 2 x 3/2 Normally Closed/Normally Open | - | 29 ~ 145 PSI (2 ~ 10 bar) | - | Air | Threaded G1/8" | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
VZBM-A-3/8"-RP-40-D-2-B2-PA10BALL VALVE ACTUATOR UNIT |
0 |
|
![]() Datasheet |
VZBM | Bulk | Active | Ball Valve | - | - | 80 ~ 116 PSI (5.5 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded 3/8" Rp | Control Valve | Free Hanging (In-Line) | - |
![]() |
VZBM-A-1/4"-RP-40-D-2-B2-PA10BALL VALVE ACTUATOR UNIT |
0 |
|
![]() Datasheet |
VZBM | Bulk | Active | Ball Valve | - | - | 80 ~ 116 PSI (5.5 ~ 8 bar) | - | Air, Inert Gas, Liquid | Threaded 1/4" Rp | Control Valve | Free Hanging (In-Line) | - |
![]() |
VSVA-B-P53BD-ZD-A2-1T1LSOLENOID VALVE |
0 |
|
![]() Datasheet |
VSVA | Bulk | Active | Solenoid Valve | 5/3 | - | -1 ~ 145 PSI (-0.1 ~ 10 bar) | - | Air | Threaded G1/8" | Solenoid Valve | Sub-Base Mount | Supply Voltage 24VDC |
![]() |
MS6-EE-3/8-10V24-SON/OFF VALVE |
0 |
|
- |
MS6 | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6-EE-1/4-10V24-SON/OFF VALVE |
0 |
|
- |
MS6 | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6-EE-1/2-V110-SON/OFF VALVE |
0 |
|
- |
MS6 | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded G1/2" | Control Valve | Chassis Mount | - |
![]() |
MS6N-EE-3/8-10V24-SON/OFF VALVE |
0 |
|
- |
MS | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6N-EE-1/4-V230-SON/OFF VALVE |
0 |
|
- |
MS | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6N-EE-3/8-V230-SON/OFF VALVE |
0 |
|
- |
MS | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6N-EE-3/8-10V24-S-ZON/OFF VALVE |
0 |
|
- |
MS | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6N-EE-3/8-V110-SON/OFF VALVE |
0 |
|
- |
MS | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |
![]() |
MS6N-EE-1/4-10V24-SON/OFF VALVE |
0 |
|
- |
MS | Bulk | Active | Control Valve | 3/2 Normally Closed | - | 58 ~ 145 PSI (4 ~ 10 bar) | - | Air, Inert Gas | Threaded | Control Valve | Chassis Mount | - |