Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
3-1609037-3LINE FILTER 250VAC 30A CHASS MNT TE Connectivity Corcom Filters |
2 |
|
![]() Datasheet |
HZ | Bulk | Last Time Buy | Single Phase | Single Stage | - | 250V | - | - | 30 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 900µH |
|
4-1609037-1LINE FILTER 250VAC 20A CHASS MNT TE Connectivity Corcom Filters |
0 |
|
![]() Datasheet |
HQ | Box | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 6mH |
![]() |
2-6609074-1LINE FILTER 80VDC 15A CHASS MNT TE Connectivity Corcom Filters |
3 |
|
![]() Datasheet |
DC | Bulk | Active | DC | Single Stage | 80V | - | - | - | 15 A | - | General Purpose | CSA, TUV, UL | -10°C ~ 55°C | Chassis Mount | Threaded Post (10-32) | - |
![]() |
3-1609037-7LINE FILTER 250VAC 20A CHASS MNT TE Connectivity Corcom Filters |
9 |
|
![]() Datasheet |
HQ | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50 ~ 60Hz | Medical | UL, VDE | - | Chassis Mount | - | - |
|
7BCF10LINE FILTER 7A CHASSIS MOUNT TE Connectivity Corcom Filters |
4 |
|
![]() Datasheet |
BCF | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 7 A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | - |
![]() |
2-1609091-5LINE FILTER 7A CHASSIS MOUNT TE Connectivity Corcom Filters |
2 |
|
![]() Datasheet |
BCF | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 7 A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | - |
![]() |
2-1609091-6LINE FILTER 16A CHASSIS MOUNT TE Connectivity Corcom Filters |
8 |
|
![]() Datasheet |
BCF | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 16 A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | - |
![]() |
7BCF10RLINE FILTER 7A CHASSIS MOUNT TE Connectivity Corcom Filters |
3 |
|
![]() Datasheet |
BCFXR | Tray | Active | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 7 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 2.43mH |
|
16BCF6RLINE FILTER 16A CHASSIS MOUNT TE Connectivity Corcom Filters |
15 |
|
![]() Datasheet |
BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 16 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 2.01mH |
![]() |
16BCF10RLINE FILTER 16A CHASSIS MOUNT TE Connectivity Corcom Filters |
8 |
|
![]() Datasheet |
BCFXR | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 16 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 2.01mH |