Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
B20-4EMI FILTER, SINGLE PHASE, 20A |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
GT-20301LINE FILTER 250VAC 3A CHASS MNT |
0 |
|
![]() Datasheet |
GT | Box | Obsolete | Single Phase | Single Stage | - | 250V | - | - | 3 A | - | General Purpose | CSA, TUV, UL | -25°C ~ 55°C | Chassis Mount | Quick Connect | - |
![]() |
NAP-30-000LINE FILTER 250VAC/VDC 30A CHASS |
2 |
|
![]() Datasheet |
NAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAP-30-681LINE FILTER 250VAC/VDC 30A CHASS |
2 |
|
![]() Datasheet |
NAP | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 30 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
MPA2-1210ELINE FILTER, 250VAC, 2A, PANEL M |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
FLLE2020ARMDLINE FILTER 300VAC/VDC 20A CHASS |
0 |
|
![]() Datasheet |
FLLE2-R | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 20 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 800µH |
![]() |
FN2415-10-29LINE FILTER 250VAC 10A CHASS MNT |
0 |
|
![]() Datasheet |
FN 2415 | Tray | Active | Single Phase | Two Stage | - | 250V | - | - | 10 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
![]() |
FLLE2020ARDDLINE FILTER 300VAC/VDC 20A CHASS |
0 |
|
![]() Datasheet |
FLLE2-R | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 20 A | 50/60Hz | General Purpose | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 800µH |
![]() |
FLLE2032AQMILINE FILTER 300VAC/VDC 32A CHASS |
0 |
|
![]() Datasheet |
FLLE2-Q | Bulk | Last Time Buy | Single Phase | Single Stage | 300V | 300V | - | - | 32 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 800µH |
![]() |
FLLE2013AUDDLINE FILTER 300VAC/VDC 13A CHASS |
0 |
|
![]() Datasheet |
FLLE2-U | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 13 A | 50/60Hz | General Purpose | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Wire Leads | 4mH |
![]() |
FLLE2013AUMBLINE FILTER 300VAC/VDC 13A CHASS |
0 |
|
![]() Datasheet |
FLLE2-U | Bulk | Last Time Buy | Single Phase | Two Stage | 300V | 300V | - | - | 13 A | 50/60Hz | Medical | ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 4mH |
![]() |
NAH-20-222LINE FILTER 250VAC/VDC 20A CHASS |
2 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-331LINE FILTER 250VAC/VDC 20A CHASS |
2 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-471LINE FILTER 250VAC/VDC 20A CHASS |
2 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-681LINE FILTER 250VAC/VDC 20A CHASS |
2 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-000LINE FILTER 250VAC/VDC 20A CHASS |
1 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-102LINE FILTER 250VAC/VDC 20A CHASS |
1 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-221LINE FILTER 250VAC/VDC 20A CHASS |
1 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-101LINE FILTER 250VAC/VDC 20A CHASS |
0 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
![]() |
NAH-20-332LINE FILTER 250VAC/VDC 20A CHASS |
0 |
|
![]() Datasheet |
NAH | Box | Active | Single Phase | Single Stage | 250V | 250V | 250 V | - | 20 A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |