| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | Type | Number of Outputs | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Grade | Voltage - Output 3 | Voltage - Output 4 | Voltage - Input (Min) | Current - Output (Max) | Power (Watts) | Efficiency | Voltage - Isolation | Qualification | Operating Temperature | Part Applications | Features | Mounting Style | Supplier Device Package | Control Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SDH02-24S05WDC DC CONVERTER 5V 2W P-DUKE Technology |
10 |
|
Datasheet |
SDH02W (2W) | 7-DIP Module, 6 Leads | Tube | Active | Isolated Module | 1 | 36V | 5V | - | - | - | - | 9V | 400mA | 2 W | 79% | 1.6 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off | Through Hole | - | - | CE | 60950-1; 62368-1 |
|
SDH02-24S12WDC DC CONVERTER 12V 2W P-DUKE Technology |
10 |
|
Datasheet |
SDH02W (2W) | 7-DIP Module, 6 Leads | Tube | Active | Isolated Module | 1 | 36V | 12V | - | - | - | - | 9V | 167mA | 2 W | 82% | 1.6 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off | Through Hole | - | - | CE | 60950-1; 62368-1 |
|
MPU02-05S15ISOLATED / 2W / VOUT: 15 P-DUKE Technology |
12 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 7V | 15V | - | - | - | - | 4.5V | 134mA | 2.01 W | 83% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-05S12ISOLATED / 2W / VOUT: 12 P-DUKE Technology |
10 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 7V | 12V | - | - | - | - | 4.5V | 167mA | 2.004 W | 83% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-12S15ISOLATED / 2W / VOUT: 15 P-DUKE Technology |
10 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 14.4V | 15V | - | - | - | - | 9.6V | 134mA | 2.01 W | 83% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-24S12ISOLATED / 2W / VOUT: 12 P-DUKE Technology |
10 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 28.8V | 12V | - | - | - | - | 19.2V | 167mA | 2.004 W | 82% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-12S12ISOLATED / 2W / VOUT: 12 P-DUKE Technology |
8 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 14.4V | 12V | - | - | - | - | 9.6V | 167mA | 2.004 W | 84% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-05S05ISOLATED / 2W / VOUT: 5 P-DUKE Technology |
8 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 7V | 5V | - | - | - | - | 4.5V | 400mA | 2 W | 81% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-24S05ISOLATED / 2W / VOUT: 5 P-DUKE Technology |
6 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 4 Leads | Tube | Active | Isolated Module | 1 | 28.8V | 5V | - | - | - | - | 19.2V | 400mA | 2 W | 80% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |
|
MPU02-24D05ISOLATED / 2W / VOUT: 5 P-DUKE Technology |
10 |
|
Datasheet |
MPU02 (2W) | 9-SIP Module, 5 Leads | Tube | Active | Isolated Module | 2 | 28.8V | 5V | -5V | - | - | - | 19.2V | 200mA, 200mA | 2 W | 81% | 5 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial), Medical | Adjustable Output | Through Hole | - | - | CB, CE, cURus, UKCA | 60601-1; 62368-1 |