Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CCG3-48-15SRDC DC CONVERTER 15V 3W TDK-Lambda |
16 |
|
![]() Datasheet |
CCG1R5-10 (3W) | 6-SMD Module | Tray | Active | Isolated Module | 1 | 18V | 76V | 15V | - | - | - | 200mA | 3 W | 1.5 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, OCP | -40°C ~ 100°C (With Derating) | 83% | - | - | Surface Mount | - | Enable, Active Low | IEC, UL, CSA, EN, CE, UKCA | 62368-1 |
![]() |
CCG3-12-05SRDC DC CONVERTER 5V 3W TDK-Lambda |
13 |
|
![]() Datasheet |
CCG1R5-10 (3W) | 6-SMD Module | Tray | Active | Isolated Module | 1 | 4.5V | 18V | 5V | - | - | - | 600mA | 3 W | 1.5 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, OCP | -40°C ~ 100°C (With Derating) | 81% | - | - | Surface Mount | - | Enable, Active Low | IEC, UL, CSA, EN, CE, UKCA | 62368-1 |
![]() |
CCG3-48-15DRDC DC CONVERTER +/-15V 3W TDK-Lambda |
12 |
|
![]() Datasheet |
CCG1R5-10 (3W) | 6-SMD Module | Tray | Active | Isolated Module | 2 | 18V | 76V | 15V | -15V | - | - | 100mA, 100mA | 3 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP | -40°C ~ 100°C (With Derating) | 83% | - | - | Surface Mount | - | Enable, Active Low | IEC, UL, CSA, EN, CE, UKCA | 62368-1 |
![]() |
CCG15-48-12DDC DC CONVERTER +/-12V 16W TDK-Lambda |
10 |
|
![]() Datasheet |
CCG15 (15W) | 6-DIP Module | Tray | Active | Isolated Module | 2 | 18V | 76V | 12V | -12V | - | - | 650mA, 650mA | 16 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP | -40°C ~ 85°C | 89% | - | - | Through Hole | - | Enable, Active Low | IEC, UL, CSA, EN, CE, UKCA | 62368-1 |
![]() |
I6A4W020A033V-0S3-RDC DC CONVERTER 3.3-15V 250W TDK-Lambda |
28 |
|
![]() Datasheet |
i6A4W (250W) | 20-SIP Module, 18 Leads | Box | Active | Non-Isolated PoL Module | 1 | 9V | 53V | 3.3 ~ 15V | - | - | - | 20A | 250 W | - | ITE (Commercial) | Remote On/Off, OCP | -40°C ~ 125°C | 97% | - | - | Through Hole | SIP | Enable, Active Low | CE | - |
![]() |
IEA48007A120V-005-RDC DC CONVERTER 12V 78W TDK-Lambda |
39 |
|
![]() Datasheet |
iEA (75W) | 8-DIP Module, 1/8 Brick | Tray | Active | Isolated Module | 1 | 36V | 75V | 12V | - | - | - | 6.5A | 78 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 125°C | 91% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
IEA48005A150V-001-RDC DC CONVERTER 15V 68W TDK-Lambda |
13 |
|
![]() Datasheet |
iEA (75W) | 8-DIP Module, 1/8 Brick | Tray | Active | Isolated Module | 1 | 36V | 75V | 15V | - | - | - | 4.5A | 68 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 125°C | 90% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
CC15-2412SFP-EDC DC CONVERTER 12V 15W TDK-Lambda |
10 |
|
![]() Datasheet |
CC-P-E (15W) | 20-DIP Module, 17 Leads | Tray | Active | Isolated Module | 1 | 18V | 36V | 12V | - | - | - | 1.25A | 15 W | 1 kV | ITE (Commercial) | - | -40°C ~ 85°C | 89% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
PXG-M15-48WS12DC DC CONVERTER 12V 15W TDK-Lambda |
13 |
|
![]() Datasheet |
PXG-M (20W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 18V | 75V | 12V | - | - | - | 1.25A | 15 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 88% | - | - | Through Hole | - | - | CE | - |
![]() |
PXG-M15-24WS12DC DC CONVERTER 12V 15W TDK-Lambda |
12 |
|
![]() Datasheet |
PXG-M (20W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 9V | 36V | 12V | - | - | - | 1.25A | 15 W | 5 kV | ITE (Commercial), Medical | Adjustable Output | -40°C ~ 105°C (With Derating) | 88.5% | - | - | Through Hole | - | - | CE | - |