Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
GQA24003A480V-N07-RDC DC CONVERTER 48V 120W TDK-Lambda |
15 |
|
![]() Datasheet |
GQA120 (120W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 18V | 36V | 48V | - | - | - | 2.5A | 120 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 105°C | 91.5% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE | - |
![]() |
GQA2W008A150V-N07-RDC DC CONVERTER 15V 120W TDK-Lambda |
12 |
|
![]() Datasheet |
GQA120 (120W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 9V | 36V | 15V | - | - | - | 8A | 120 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 105°C | 89% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE | - |
![]() |
GQA2W004A280V-N07-RDC DC CONVERTER 28V 120W TDK-Lambda |
8 |
|
![]() Datasheet |
GQA120 (120W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 9V | 36V | 28V | - | - | - | 4.28A | 120 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 105°C | 89% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CE | - |
![]() |
PXD60-24WS3P3DC DC CONVERTER 3.3V 40W TDK-Lambda |
20 |
|
![]() Datasheet |
PXD60 (60W) | 6-DIP Module | Tube | Active | Isolated Module | 1 | 9V | 36V | 3.3V | - | - | - | 12A | 40 W | 1.6 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, Remote Sense | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 62368-1 |
![]() |
PXD60-48WD24DC DC CONVERTER +/-24V 60W TDK-Lambda |
10 |
|
![]() Datasheet |
PXD60 (60W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 18V | 75V | 24V | -24V | - | - | 1.25A, 1.25A | 60 W | 1.6 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, Remote Sense | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 62368-1 |
![]() |
PXD60-24WD24DC DC CONVERTER +/-24V 60W TDK-Lambda |
5 |
|
![]() Datasheet |
PXD60 (60W) | 6-DIP Module | Tube | Active | Isolated Module | 2 | 9V | 36V | 24V | -24V | - | - | 1.25A, 1.25A | 60 W | 1.6 kV | ITE (Commercial) | Adjustable Output, Remote On/Off, Remote Sense | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | - | Enable, Active High | CE, UKCA | 62368-1 |
![]() |
GQA2W024A050V-NP7-RDC-DC, PCB MOUNT, QUARTER BRICK, TDK-Lambda |
15 |
|
![]() Datasheet |
GQA120 (120W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 9V | 36V | 5V | - | - | - | 24A | 120 W | 2.25 kV | ITE (Commercial) | Adjustable Output, Baseplate, Remote Sense | -40°C ~ 105°C | 90% | - | - | Through Hole | Quarter Brick | - | CE, UKCA | 60950-1; 62368-1 |
|
PAH300S48-28DC DC CONVERTER 28V 300W TDK-Lambda |
2 |
|
![]() Datasheet |
PAH300 (300W) | 9-DIP Module, 1/2 Brick | Bulk | Active | Isolated Module | 1 | 36V | 76V | 28V | - | - | - | 11A | 300 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OVP | -40°C ~ 100°C | 90% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
CN30A110-5DC DC CONVERTER 5V 30W TDK-Lambda |
2 |
|
![]() Datasheet |
CN-A110 (30W) | 8-DIP Module, 1/4 Brick | Bulk | Active | Isolated Module | 1 | 60V | 160V | 5V | - | - | - | 6A | 30 W | 3 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 100°C | 83% | - | - | Through Hole | - | - | - | - |
![]() |
CN30A110-15DC DC CONVERTER 15V 30W TDK-Lambda |
2 |
|
![]() Datasheet |
CN-A110 (30W) | 8-DIP Module, 1/4 Brick | Bulk | Active | Isolated Module | 1 | 60V | 160V | 15V | - | - | - | 2A | 30 W | 3 kV | ITE (Commercial) | Remote On/Off | -40°C ~ 100°C | 84% | - | - | Through Hole | - | - | - | - |