| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | Type | Number of Outputs | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Grade | Voltage - Output 3 | Voltage - Output 4 | Voltage - Input (Min) | Current - Output (Max) | Power (Watts) | Efficiency | Voltage - Isolation | Qualification | Operating Temperature | Part Applications | Features | Mounting Style | Supplier Device Package | Control Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RP15-4815DA/N-HCDC DC CONVERTER +/-15V 15W |
2,581 |
|
Datasheet |
POWERLINE RP15-A (15W) | 6-DIP Module, 4 Leads | Tube | Active | Isolated Module | 2 | 75V | 15V | -15V | - | - | - | 36V | 500mA, 500mA | 15 W | 88% | 1.6 kV | - | -40°C ~ 85°C | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | Through Hole | - | Enable, Active Low | - | - |
|
RP15-4815DA/P-HCDC DC CONVERTER +/-15V 15W |
2,671 |
|
Datasheet |
POWERLINE RP15-A (15W) | 6-DIP Module, 4 Leads | Tube | Active | Isolated Module | 2 | 75V | 15V | -15V | - | - | - | 36V | 500mA, 500mA | 15 W | 88% | 1.6 kV | - | -40°C ~ 85°C | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | Through Hole | - | Enable, Active High | - | - |
|
RP15-4815SAW/N-HCDC DC CONVERTER 15V 15W |
3,613 |
|
Datasheet |
POWERLINE RP15-AW (15W) | 6-DIP Module, 5 Leads | Tube | Active | Isolated Module | 1 | 75V | 15V | - | - | - | - | 18V | 1A | 15 W | 87% | 1.6 kV | - | -40°C ~ 85°C | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | Through Hole | - | Enable, Active Low | - | - |
|
RP15-4815SAW/P-HCDC DC CONVERTER 15V 15W |
2,051 |
|
Datasheet |
POWERLINE RP15-AW (15W) | 6-DIP Module, 5 Leads | Tube | Active | Isolated Module | 1 | 75V | 15V | - | - | - | - | 18V | 1A | 15 W | 87% | 1.6 kV | - | -40°C ~ 85°C | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | Through Hole | - | Enable, Active High | - | - |
|
RP15-483.3SAW/N-HCDC DC CONVERTER 3.3V 15W |
3,419 |
|
Datasheet |
POWERLINE RP15-AW (15W) | 6-DIP Module, 5 Leads | Tube | Active | Isolated Module | 1 | 75V | 3.3V | - | - | - | - | 18V | 4A | 15 W | 86% | 1.6 kV | - | -40°C ~ 85°C | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | Through Hole | - | Enable, Active Low | - | - |
|
RP15-483.3SAW/P-HCDC DC CONVERTER 3.3V 15W |
2,939 |
|
Datasheet |
POWERLINE RP15-AW (15W) | 6-DIP Module, 5 Leads | Tube | Active | Isolated Module | 1 | 75V | 3.3V | - | - | - | - | 18V | 4A | 15 W | 86% | 1.6 kV | - | -40°C ~ 85°C | ITE (Commercial) | Remote On/Off, OCP, OVP, SCP | Through Hole | - | Enable, Active High | - | - |
|
DCE0133V2NBSCDC DC CONVERTER 12V 396W |
2,441 |
|
Datasheet |
DCE (400W) | Eighth Brick | Tray | Active | Isolated Module, Digital | 1 | 75V | 12V | - | - | - | - | 36V | 33A | 396 W | 95.5% | 2.25 kV | - | -40°C ~ 85°C (With Derating) | ITE (Commercial) | OCP, OTP, OVP, SCP | Through Hole | Eighth Brick | - | CE, cURus | - |
|
REM3-0505D/A/CTRLDC DC CONVERTER +/-5V 3W |
4,387 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 9V | 5V | -5V | - | - | - | 4.5V | 300mA, 300mA | 3 W | 83% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-1205D/A/CTRLDC DC CONVERTER +/-5V 3W |
3,611 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 18V | 5V | -5V | - | - | - | 9V | 300mA, 300mA | 3 W | 83.5% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-2405D/A/CTRLDC DC CONVERTER +/-5V 3W |
2,896 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 36V | 5V | -5V | - | - | - | 18V | 300mA, 300mA | 3 W | 83% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-4805D/A/CTRLDC DC CONVERTER +/-5V 3W |
4,647 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 75V | 5V | -5V | - | - | - | 36V | 300mA, 300mA | 3 W | 83% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-0512D/A/CTRLDC DC CONVERTER +/-12V 3W |
3,546 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 9V | 12V | -12V | - | - | - | 4.5V | 125mA, 125mA | 3 W | 86% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-1212D/A/CTRLDC DC CONVERTER +/-12V 3W |
4,792 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 18V | 12V | -12V | - | - | - | 9V | 125mA, 125mA | 3 W | 87.5% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-2412D/A/CTRLDC DC CONVERTER +/-12V 3W |
2,316 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 36V | 12V | -12V | - | - | - | 18V | 125mA, 125mA | 3 W | 86% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-4812D/A/CTRLDC DC CONVERTER +/-12V 3W |
4,210 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 75V | 12V | -12V | - | - | - | 36V | 125mA, 125mA | 3 W | 86% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-0515D/A/CTRLDC DC CONVERTER +/-15V 3W |
3,097 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 9V | 15V | -15V | - | - | - | 4.5V | 100mA, 100mA | 3 W | 86% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-1215D/A/CTRLDC DC CONVERTER +/-15V 3W |
3,856 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 18V | 15V | -15V | - | - | - | 9V | 100mA, 100mA | 3 W | 86.5% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-2415D/A/CTRLDC DC CONVERTER +/-15V 3W |
4,991 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 36V | 15V | -15V | - | - | - | 18V | 100mA, 100mA | 3 W | 86% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-4815D/A/CTRLDC DC CONVERTER +/-15V 3W |
2,383 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 7 Leads | Tube | Active | Isolated Module | 2 | 75V | 15V | -15V | - | - | - | 36V | 100mA, 100mA | 3 W | 86% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | - | - |
|
REM3-2405DW/ADC DC CONVERTER +/-5V 3W |
3,945 |
|
Datasheet |
MEDLINE REM3 (3W) | 24-DIP Module, 6 Leads | Tube | Active | Isolated Module | 2 | 36V | 5V | -5V | - | - | - | 9V | 300mA, 300mA | 3 W | 83% | 5 kV | - | -40°C ~ 105°C | ITE (Commercial), Medical | Remote On/Off, OCP, OVP, SCP, UVLO | Through Hole | - | - | - | - |