| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | Type | Number of Outputs | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Grade | Voltage - Output 3 | Voltage - Output 4 | Voltage - Input (Min) | Current - Output (Max) | Power (Watts) | Efficiency | Voltage - Isolation | Qualification | Operating Temperature | Part Applications | Features | Mounting Style | Supplier Device Package | Control Features | Approval Agency | Standard Number |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RP40Q-11005SRUWB/P-HC40W DC/DC-CONVERTER 'POWERLINE' |
4,865 |
|
Datasheet |
RP40Q-RUW (40W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 160V | 5V | - | - | - | - | 14V | 8A | 40 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Adjustable Output, Baseplate, Heat Sink, Remote On/Off, Remote Sense, Standby Output | Through Hole | Quarter Brick | Enable, Active High | CE, cURus | 62368-1 |
|
RP40Q-11048SRUWB/N-HC40W DC/DC-CONVERTER 'POWERLINE' |
2,486 |
|
Datasheet |
RP40Q-RUW (40W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 160V | 48V | - | - | - | - | 14V | 830mA | 40 W | 90% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Adjustable Output, Baseplate, Heat Sink, Remote On/Off, Remote Sense, Standby Output | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus | 62368-1 |
|
RP40Q-11048SRUWB/P-HC40W DC/DC-CONVERTER 'POWERLINE' |
4,837 |
|
Datasheet |
RP40Q-RUW (40W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 160V | 48V | - | - | - | - | 14V | 830mA | 40 W | 90% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Adjustable Output, Baseplate, Heat Sink, Remote On/Off, Remote Sense, Standby Output | Through Hole | Quarter Brick | Enable, Active High | CE, cURus | 62368-1 |
|
RP40Q-11015SRUWB/P-HC40W DC/DC-CONVERTER 'POWERLINE' |
2,723 |
|
Datasheet |
RP40Q-RUW (40W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 160V | 15V | - | - | - | - | 14V | 2.67A | 40 W | 91% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Adjustable Output, Heat Sink, Remote On/Off, Remote Sense, Standby Output | Through Hole | Quarter Brick | Enable, Active High | CE, cURus | 62368-1 |
|
RP40Q-11005SRUWB/N-HC40W DC/DC-CONVERTER 'POWERLINE' |
3,105 |
|
Datasheet |
RP40Q-RUW (40W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 160V | 5V | - | - | - | - | 14V | 8A | 40 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Adjustable Output, Baseplate, Heat Sink, Remote On/Off, Remote Sense, Standby Output | Through Hole | Quarter Brick | Enable, Active Low | CE, cURus | 62368-1 |
|
IRH-24/10.5-W80PB-C16V - 160V DC I/P, 24V 250W O/P, |
2,358 |
|
Datasheet |
IRH-W80 (250W) | Half Brick | Tray | Active | Isolated Module | 1 | 160V | 24V | - | - | - | - | 16V | 10.5A | 252 W | 90% | 4.242 kV | - | -40°C ~ 100°C (With Derating) | ITE (Commercial), Railway | Adjustable Output, Baseplate, Heat Sink, Remote On/Off, Remote Sense | Through Hole | Half Brick | Enable, Active High | CE, cURus | 60950-1 |
|
AEQ12-300BP0.5AEQ-SERIES +12VDC INPUT, +/-300V |
3,476 |
|
Datasheet |
UltraVolt© AEQ | 6-DIP Module | Box | Active | High Voltage - Isolated Module | 2 | 12.12V | 300V | -300V | - | - | - | 11.88V | 833µA, 833µA | 500 mW | - | 1.5 kV | - | -30°C ~ 70°C | ITE (Commercial) | Adjustable Output | Through Hole | - | - | CE, cURus | 62368-1 |
|
CQB150-300S15DC DC CONVERTER 15V 150W |
2,304 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 15V | - | - | - | - | 180V | 10A | 150 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active High | CE, cURus | 60950-1 |
|
CQB150-300S28DC DC CONVERTER 28V 151W |
2,092 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 28V | - | - | - | - | 180V | 5.4A | 151 W | 88.5% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active High | CE, cURus | 60950-1 |
|
CQB150-300S48DC DC CONVERTER 48V 154W |
4,550 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 48V | - | - | - | - | 180V | 3.2A | 154 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active High | CE, cURus | 60950-1 |
|
CQB150-300S05NDC DC CONVERTER 5V 150W |
2,471 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 5V | - | - | - | - | 180V | 30A | 150 W | 86% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | CE, cURus | 60950-1 |
|
CQB150-300S12NDC DC CONVERTER 12V 150W |
2,708 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 12V | - | - | - | - | 180V | 12.5A | 150 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | CE, cURus | 60950-1 |
|
CQB150-300S15NDC DC CONVERTER 15V 150W |
4,127 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 15V | - | - | - | - | 180V | 10A | 150 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | CE, cURus | 60950-1 |
|
CQB150-300S24NDC DC CONVERTER 24V 151W |
4,508 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 24V | - | - | - | - | 180V | 6.3A | 151 W | 88.5% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | CE, cURus | 60950-1 |
|
CQB150-300S28NDC DC CONVERTER 28V 151W |
2,160 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 28V | - | - | - | - | 180V | 5.4A | 151 W | 88.5% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | CE, cURus | 60950-1 |
|
CQB150-300S48NDC DC CONVERTER 48V 154W |
4,280 |
|
Datasheet |
CQB150-300S (150W) | - | Tray | Active | Isolated Module | 1 | 425V | 48V | - | - | - | - | 180V | 3.2A | 154 W | 89% | 3 kV | - | -40°C ~ 105°C (With Derating) | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Through Hole | - | Enable, Active Low | CE, cURus | 60950-1 |
|
CN100A110-12/CODC-DC, PCB MOUNT, QUARTER BRICK, |
3,916 |
|
Datasheet |
CN-A110 (200W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 13.2V | 12V | - | - | - | - | 10.8V | 8.4A | 101 W | 88% | 3 kV | - | -40°C ~ 100°C | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | Through Hole | Quarter Brick | Enable, Active Low | CE, CSA, EN, FCC, IEC, UKCA, UL | 60950-1; 62368-1 |
|
CN100A110-15/CODC-DC, PCB MOUNT, QUARTER BRICK, |
4,742 |
|
Datasheet |
CN-A110 (200W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 16.5V | 15V | - | - | - | - | 13.5V | 6.7A | 101 W | 88% | 3 kV | - | -40°C ~ 100°C | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | Through Hole | Quarter Brick | Enable, Active Low | CE, CSA, EN, FCC, IEC, UKCA, UL | 60950-1; 62368-1 |
|
CN100A110-24/CODC-DC, PCB MOUNT, QUARTER BRICK, |
3,958 |
|
Datasheet |
CN-A110 (200W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 26.4V | 24V | - | - | - | - | 21.6V | 4.2A | 101 W | 88% | 3 kV | - | -40°C ~ 100°C | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | Through Hole | Quarter Brick | Enable, Active Low | CE, CSA, EN, FCC, IEC, UKCA, UL | 60950-1; 62368-1 |
|
CN100A110-5/CODC-DC, PCB MOUNT, QUARTER BRICK, |
3,567 |
|
Datasheet |
CN-A110 (200W) | Quarter Brick | Bulk | Active | Isolated Module, Conformal Coated | 1 | 6V | 5V | - | - | - | - | 4.5V | 20A | 100 W | 85% | 3 kV | - | -40°C ~ 100°C | ITE (Commercial) | Adjustable Output, Baseplate, Remote On/Off, Remote Sense | Through Hole | Quarter Brick | Enable, Active Low | CE, CSA, EN, FCC, IEC, UKCA, UL | 60950-1; 62368-1 |