Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RFT-30Y54DC-DC,14-160V INPUT, 54V/0.56A O Bel Power Solutions |
114 |
|
![]() Datasheet |
RFT-30Y (30W) | 6-DIP Module | Bulk | Active | Isolated Module | 1 | 14V | 160V | 54V | - | - | - | 556mA | 30 W | 3 kV | ITE (Commercial) | Adjustable Output | -40°C ~ 105°C | 89% | - | - | Through Hole | - | - | cCSAus, CE, UKCA | 62368-1 |
![]() |
HBC25ZH-NTDC DC CONVERTER 12V 300W Bel Power Solutions |
0 |
|
![]() Datasheet |
HBC (300W) | 9-DIP Module, 1/2 Brick | Bulk | Obsolete | Intermediate Bus Converter | 1 | 36V | 75V | 12V | - | - | - | 25A | 300 W | 1.5 kV | ITE (Commercial) | - | -40°C ~ 110°C | 92% | - | - | Through Hole | - | - | - | - |
|
20IMX15-0503-8RGDC DC CONVERTER 5.1V 3.3V 15W Bel Power Solutions |
0 |
|
![]() Datasheet |
Melcher IMX15 (15W) | 17-DIP Module | Bulk | Active | Isolated Module, Conformal Coated | 2 | 8.4V | 36V | 5.1V | 3.3V | - | - | 1.35A, 1.35A | 15 W | 2.1 kV | ITE (Commercial), Railway | OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 84% | - | - | Through Hole | - | - | - | - |
![]() |
0RQP-X5M12BGDC-DC 48-60VIN 12V 125AOUT 1500W Bel Power Solutions |
352 |
|
![]() Datasheet |
0RQP-X5M12B (1500W) | Quarter Brick | Tray | Active | Isolated Module | 1 | 48V | 60V | 12V | - | - | - | 125A | 1.5 kW | 500 V | ITE (Commercial) | Baseplate, Remote On/Off | -20°C ~ 85°C (With Derating) | 97.3% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CSA, UL | - |
![]() |
HBS050ZG-ANT9DC DC CONVERTER 5V 50W Bel Power Solutions |
0 |
|
![]() Datasheet |
HBS (50W) | 9-DIP Module | Bulk | Obsolete | Isolated Module | 1 | 34V | 75V | 5V | - | - | - | 10A | 50 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP | -40°C ~ 100°C | 82% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
24IBX15-50-0ZGDC DC CONVERTER 50-160V Bel Power Solutions |
0 |
|
![]() Datasheet |
Melcher IBX15 | 17-DIP Module, 10 Leads | Bulk | Active | Non-Isolated PoL Module, Conformal Coated | 1 | 15.4V | 160V | 50 ~ 160V | - | - | - | 1.6A | - | - | ITE (Commercial) | OTP, UVLO | -40°C ~ 70°C | 93% | - | - | Through Hole | - | - | - | - |
![]() |
RQB-100Y48DC,14-160V INPUT, 48V/2.08A Bel Power Solutions |
43 |
|
![]() Datasheet |
RQB-100Y | Quarter Brick | Tray | Active | Isolated Module | 1 | 14V | 160V | 48V | - | - | - | 2.08A | 100 W | 3 kV | ITE (Commercial), Railway | Adjustable Output, Remote On/Off, Remote Sense | -40°C ~ 105°C | 90% | - | - | Through Hole | Quarter Brick | - | CE, CSAus | 62368-1 |
|
24IMX70-24-24-0GDC DC CONVERTER 24V 24V 70W Bel Power Solutions |
0 |
|
![]() Datasheet |
Melcher IMX70 (70W) | 19-DIP Module, 17 Leads | Bulk | Active | Isolated Module, Conformal Coated | 2 | 15V | 33.6V | 24V | 24V | - | - | 1.3A, 1.3A | 70 W | 2.1 kV | ITE (Commercial) | OCP, OTP, SCP | -40°C ~ 95°C | 90% | - | - | Through Hole | - | - | - | - |
![]() |
ASQ24S10050-NS00DC DC CONVERTER 5V 50W Bel Power Solutions |
0 |
|
![]() Datasheet |
ASQ24 (50W) | 8-SMD Module, 1/8 Brick | Bulk | Obsolete | Isolated Module | 1 | 18V | 36V | 5V | - | - | - | 10A | 50 W | 2 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, UVLO | -55°C ~ 85°C | 86% | - | - | Surface Mount | Eighth Brick | Enable, Active Low | - | - |
|
40IMX35D15D15-8GDC DC CONVERTER 15V 15V 15V 35W Bel Power Solutions |
3 |
|
![]() Datasheet |
Melcher IMX35 (35W) | 19-DIP Module | Bulk | Active | Isolated Module, Conformal Coated | 4 | 18V | 75V | 15V | 15V | 15V | - | 600mA, 600mA, 600mA | 35 W | 1.5 kV | ITE (Commercial) | OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 89% | - | - | Through Hole | - | - | - | - |