Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Function | Voltage - Supply | Trip Range | Delay Time | Mounting Type | Termination Style | Features | Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PGR-4700-120SENS GRND FAULT RELAY 120V SUP |
0 |
|
![]() Datasheet |
POWR-GARD® | Bulk | Active | Ground Fault | 120VAC | 0.01 ~ 3A | 0 ~ 1.5s | DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -10°C ~ 60°C |
![]() |
D0900.0010ARC DETECTING RELAY AC |
0 |
|
![]() Datasheet |
D0900 | Bulk | Discontinued at Digi-Key | Arc-Flash | 220 ~ 250VAC | 2 ~ 24 klux | - | DIN Rail | Screw Terminal | - | -25°C ~ 70°C |
![]() |
SE-601-0TDC GROUND FAULT RELAY 32-70 VDC |
0 |
|
![]() Datasheet |
SE-601 | Bulk | Active | Ground Fault, Overcurrent | 48VDC | 1 ~ 20mA | 0.05 ~ 2.5s | Chassis Mount, DIN Rail | Screw Terminal | Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-704-0TSENSITIVE GF RELAY 32 70 VDC |
0 |
|
![]() Datasheet |
SE-704 | Bulk | Active | Ground Fault | 48VDC | 0.01 ~ 5A | 0.03 ~ 20s | DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-601-0U-CCSE-601-0U WITH CONFORMAL COATING |
0 |
|
![]() Datasheet |
- | Bulk | Active | Ground Fault, Overcurrent | 120 ~ 240VAC/DC | 1 ~ 20mA | 0.05 ~ 2.5s | Chassis Mount, DIN Rail | Screw Terminal | Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
56270EARTHLEAKAGE RELAY RH99P WITH MA |
0 |
|
- |
VigiPacT | Box | Obsolete | Ground Fault, Overcurrent | 12 ~ 24VAC, 12 ~ 48VDC | 30mA ~ 30A | 0 ~ 4.5s | Panel Mount | - | Manual Reset | -35°C ~ 70°C |
![]() |
56272EARTHLEAKAGE RELAY RH99P WITH MA |
0 |
|
![]() Datasheet |
VigiPacT | Box | Obsolete | Ground Fault, Overcurrent | 110 ~ 130VAC | 30mA ~ 30A | 0 ~ 4.5s | Panel Mount | Screw Terminal | Manual Reset, Test Button | -35°C ~ 70°C |
![]() |
56273EARTHLEAKAGE RELAY RH99P WITH MA |
0 |
|
![]() Datasheet |
VigiPacT | Box | Obsolete | Ground Fault, Overcurrent | 220 ~ 240VAC | 30mA ~ 30A | 0 ~ 4.5s | Panel Mount | Screw Terminal | Manual Reset, Test Button | -35°C ~ 70°C |
![]() |
WD81OU-003WD81OU-003=RELAY, OVR/UNDR FRE |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
56230EARTHLEAKAGE RELAY RH10P 30 MA 2 |
0 |
|
![]() Datasheet |
VigiPacT | Box | Obsolete | Ground Fault, Overcurrent | 220 ~ 240VAC | 30mA | - | Panel Mount | Screw Terminal | Manual Reset, Test Button | -35°C ~ 70°C |
![]() |
WUV-125DCWUV-125DC=WILMAR UNDERVOLTAGE |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
WUV-48DCWUV-48DC=DC UNDERVOLTAGE RELAY |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
WUV-560DCWUV-560DC=WILMAR UNDERVOLTAGE |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
PGR-4700-240SENS GRND FAULT RELAY 240V SUP |
0 |
|
![]() Datasheet |
POWR-GARD® | Bulk | Active | Ground Fault | 240VAC | 0.01 ~ 3A | 0 ~ 1.5s | DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -10°C ~ 60°C |
![]() |
8-1618103-8WCT1-26DC-1=WILMAR OVERCURRENT |
0 |
|
![]() Datasheet |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
9-1618103-0WCT1-26DC-1A=OVERCURRENT RELAY |
0 |
|
![]() Datasheet |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
6-1618071-7255-6X=WILMAR OVER/UNDERVOLTAG |
0 |
|
![]() Datasheet |
250 | Bulk | Active | Overvoltage, Undervoltage | 460VAC | 345 ~ 575VAC | - | Chassis Mount | Stud | - | -40°C ~ 85°C |
|
1-1618065-8PROTECTIVE RELAY 120V |
0 |
|
![]() Datasheet |
1800 | Bulk | Active | - | 120VAC | - | - | Chassis Mount | Stud | - | -25°C ~ 70°C |
![]() |
8-1618103-9WCT1-26DC-10=WILMAR OVERCURREN |
0 |
|
![]() Datasheet |
- | Bulk | Active | - | - | - | - | - | - | - | - |
![]() |
WOVT3-200WOVT3-200=WILMAR OVERVOLTAGE R |
0 |
|
- |
- | Bulk | Active | - | - | - | - | - | - | - | - |