Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Disconnect Type | Number of Positions | Number of Levels | Terminal - Width | Termination Style | Current - IEC | Voltage - IEC | Current - UL | Voltage - UL | Wire Gauge or Range - AWG | Wire Gauge or Range - mm² | Features | Color | Fuse Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
3592.2THREE-LEVEL INITIATOR TERM.MULTI |
0 |
|
![]() Datasheet |
ZIKD | Box | Active | Feed Through | - | 6 | 3; 1 Grounded | 5.1mm | Push In, Spring | 24 A | 500V | 15 A | 300V | 12-20 AWG | 0.5-4mm² | - | Beige | - |
![]() |
283-9022-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
![]() Datasheet |
- | Box | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In, Spring | 76 A | 800V | - | - | 6-24 AWG | 0.2-16mm² | - | Orange | - |
![]() |
283-9922-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
![]() Datasheet |
- | Box | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In, Spring | - | - | - | - | 6-24 AWG | 0.2-16mm² | - | Gray | - |
![]() |
283-9062-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
- |
- | Bulk | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In | 76 A | 800V | - | - | 6-24 AWG | 0.2-16mm² | - | Yellow | - |
![]() |
283-9032-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
- |
- | Bulk | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In | 76 A | 800V | - | - | 6-24 AWG | 0.2-16mm² | - | Red | - |
![]() |
283-9052-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
- |
- | Bulk | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In | 76 A | 800V | - | - | 6-24 AWG | 0.2-16mm² | - | Black | - |
![]() |
2010-13063-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
![]() Datasheet |
TOPJOB®S | Box | Active | Feed Through | - | 3 | 1 | 10.0mm | Push In, Spring | 76 A | 800V | 65 A | 600V | 6-20 AWG | 0.5-16mm² | - | Yellow | - |
![]() |
3211427CONN TERM BLK FEED THRU 12-26AWG |
0 |
|
![]() Datasheet |
CLIPLINE PTTB | Box | Active | Feed Through | - | 4 | 2 | 5.2mm | Push In, Spring | 20 A | 500V | 20 A | 300V | 12-26 AWG | 0.14-4mm² | Diode | Gray | - |
![]() |
3210282CONN TERM BLK FEED THRU 12-26AWG |
0 |
|
![]() Datasheet |
CLIPLINE PTTBS | Box | Active | Feed Through | - | 4 | 2; Connected | 5.2mm | Push In, Spring | 20 A | 500V | 20 A | 300V | 12-26 AWG | 0.14-4mm² | Diode | Gray | - |
![]() |
783-6042-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
![]() Datasheet |
TOPJOB®S | Box | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In, Spring | 76 A | 1000V | - | - | 6-24 AWG | 0.2-16mm² | - | Blue | - |
![]() |
783-9922-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
![]() Datasheet |
TOPJOB®S | Box | Active | Feed Through | - | 2 | 1 | 12.0mm | Push In, Spring | - | - | - | - | 6-24 AWG | 0.2-16mm² | - | Gray | - |
![]() |
CDL4U(E)MOV30VDIN TERM BLK, SCREW, SURGE SUPPR |
0 |
|
- |
CDL4U | Bulk | Active | Feed Through | - | 4 | 2; Connected | 12.0mm | Screw | - | - | - | 30V | 10-22 AWG | - | Varistor | Gray | - |
![]() |
CYDLG2.5(I.S)DIN TERM BLK, SCREW, DBL LEVEL |
0 |
|
![]() Datasheet |
CYDL | Bulk | Active | Feed Through | - | 4 | 2; Connected and Grounded | 5.0mm | Screw | 24 A | 500V | 20 A | 300V | 12-24 AWG | 0.2-2.5mm² | - | Gray | - |
![]() |
NSYTRP22SCPUSH-INTERMINAL KNIFEDISC 2PT 2, |
0 |
|
![]() Datasheet |
Linergy TR | Box | Active | Disconnect | Switch, Knife | 2 | 1 | 5.2mm | Push In | 20 A | 400V | 20 A | 300V | - | 0.14-4mm² | - | Gray | - |
![]() |
1022350000WDK 2.5V GE |
0 |
|
![]() Datasheet |
W | Box | Active | Feed Through | - | 4 | 2; Connected | 5.1mm | Screw | 24 A | 400V | 20 A | 600V | 12-22 AWG | 0.5-4mm² | - | Yellow | - |
![]() |
1441.2EX-EARTH TERMINAL CERTIFIED ACC. |
0 |
|
![]() Datasheet |
SL | Box | Active | Ground, Earth | - | 2 | 1 | 12.0mm | Screw | - | - | - | - | 4-10 AWG | 2.5-16mm² | - | Green, Yellow | - |
![]() |
1066350INTERCONNECT MISC |
0 |
|
- |
CLIPLINE MUTTB | Bulk | Active | Feed Through | - | 4 | 2 | 5.2mm | Push In, Spring | 22 A | 500V | 20 A | 500V | 12-24 AWG | 0.2-4mm² | - | Gray | - |
![]() |
2002-17013-CONDUCTOR THROUGH TERMINAL BLO |
0 |
|
![]() Datasheet |
TOPJOB®S | Box | Active | Feed Through | - | 3 | 1 | 5.2mm | Push In, Spring | 16 A | 400V | 15 A | 300V | 12-22 AWG | 0.25-4mm² | - | Gray | - |
![]() |
1013200000CONN TERM BLK DISCONN 12-26AWG |
0 |
|
![]() Datasheet |
W | - | Obsolete | Disconnect | Component, Removable Plug | 2 | 1 | 5.1mm | Screw | 14 A | 500V | 10 A | 300V | 12-26 AWG | 0.5-4mm² | Diode | Beige | - |
![]() |
2202-63073-CONDUCTOR GROUND TERMINAL BLOC |
0 |
|
![]() Datasheet |
TOPJOB®S, 2202 | Box | Active | Ground, Earth | - | 3 | 1 | 5.2mm | Push In, Spring | - | - | - | - | 12-22 AWG | 0.25-4mm² | - | Green, Yellow | - |