| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Part Status | Type | Disconnect Type | Number of Levels | Terminal - Width | Termination Style | Current - IEC | Voltage - IEC | Number of Positions | Current - UL | Voltage - UL | Fuse Type | Wire Gauge or Range - AWG | Color | Wire Gauge or Range - mm² | Features |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2002-1981/1000-4292-CONDUCTOR FUSE TERMINAL BLOCK; |
4,874 |
|
Datasheet |
TOPJOB®S | Box | Active | Disconnect | Fuse | 1 | 5.2mm | Push In, Spring | 10 A | 400V | 2 | 10 A | 12V | Blade | 12-22 AWG | Gray | 0.25-4mm² | LED, Resistor |
|
2002-1981/1000-4142-CONDUCTOR FUSE TERMINAL BLOCK; |
3,897 |
|
Datasheet |
TOPJOB®S | Box | Active | Disconnect | Fuse | 1 | 5.2mm | Push In, Spring | 10 A | 400V | 2 | 10 A | 48V | Blade | 12-22 AWG | Gray | 0.25-4mm² | LED, Resistor |
|
2712970000AAP12 10/4X2.5 LO-LI WT |
2,866 |
|
Datasheet |
AAP | Box | Active | Feed Through | - | 1 | 10.0mm | Push In | 57 A | 800V | 5 | 55 A | 600V | - | 6-28 AWG | Beige | 0.5-10mm² | - |
|
17192.2EARTH DOUBLE-LEVEL TERMINAL |
3,638 |
|
Datasheet |
SSLD | Box | Active | Feed Through | - | 2; Connected | 10.1mm | Screw | - | - | 4 | - | - | - | 6-18 AWG | Green, Yellow | 0.2-16mm² | - |
|
1763260000CONN TERM BLK DISCONN 12-26AWG |
4,594 |
|
Datasheet |
Z | Bulk | Obsolete | Disconnect | Fuse, Removable Plug | 2 | 5.1mm | Push In, Spring | 6.3 A | 400V | 4 | 10 A | 300V | 5mm x 20mm | 12-26 AWG | Beige | 0.5-4mm² | LED |
|
|
3210268CONN TERM BLK FEED THRU 12-26AWG |
4,055 |
|
Datasheet |
CLIPLINE PTT | Bulk | Obsolete | Feed Through | - | 2 | 5.2mm | Push In | 16 A | 400V | 4 | 16 A | 300V | - | 12-26 AWG | Blue | 0.14-4mm² | - |
|
280-588/280-3234-CONDUCTOR SENSOR TERMINAL BLOC |
4,492 |
|
Datasheet |
- | Box | Active | Disconnect, Feed Through, Isolated (2) | Component Plug | 4 | 6.0mm | Push In, Spring | 6.3 A | 125V | 6 | - | - | - | 12-28 AWG | Gray | 0.08-2.5mm² | - |
|
280-588/280-3204-CONDUCTOR SENSOR TERMINAL BLOC |
2,294 |
|
Datasheet |
- | Box | Active | Disconnect, Feed Through, Isolated (2) | Component Plug | 4 | 6.0mm | Push In, Spring | 6.3 A | 125V | 6 | - | - | - | 12-28 AWG | Gray | 0.08-2.5mm² | - |
|
2816990000A2T 4 FS-FT 60-150V BK |
4,996 |
|
Datasheet |
A | Box | Active | Disconnect | Fuse | 2 | 6.1mm | Push In | 6.3 A | 150V | 4 | - | - | 5mm x 20mm | 10-26 AWG | Black | 0.5-4mm² | Diode |
|
2816980000A2T 4 FS-FT 30-70V BK |
4,095 |
|
Datasheet |
A | Box | Active | Disconnect | Fuse | 2 | 6.1mm | Push In | 6.3 A | 70V | 4 | - | - | 5mm x 20mm | 10-26 AWG | Black | 0.5-4mm² | Diode |
|
281-915/281-410COMPONENT TERMINAL BLOCK; 2-COND |
3,488 |
|
Datasheet |
- | Box | Active | Feed Through | - | 1 | 6.0mm | Push In, Spring | 500 mA | - | 2 | - | - | - | 12-28 AWG | Gray | 0.08-4mm² | Diode |
|
2718316CONN TERM BLK FEED THRU 14-30AWG |
3,156 |
|
Datasheet |
CLIPLINE VIOK | Bulk | Last Time Buy | Feed Through (3), Isolated | - | 4; 1 Grounded | 6.2mm | Screw | 24 A | 400V | 7 | 15 A | 300V | - | 14-30 AWG | Blue | 0.2-4mm² | - |
|
NSYTRV62TTDSCRW TRMINL DSCNT MSRNG TRNSDCR |
3,317 |
|
Datasheet |
Linergy TR | Box | Active | Disconnect | Switch, Lever | 1 | 8.2mm | Screw | 30 A | 500V | 2 | 30 A | 600V | - | - | Gray | 0.2-10mm² | - |
|
280-5862-CONDUCTOR ACTUATOR SUPPLY TERM |
2,114 |
|
Datasheet |
- | Box | Active | Feed Through, Isolated | - | 2 | 6.0mm | Push In, Spring | 20 A | 400V | 3 | - | - | - | 12-28 AWG | Gray | 0.08-2.5mm² | - |
|
3002618PT 4-PE/L/TG |
4,624 |
|
Datasheet |
CLIPLINE PT | Bulk | Active | Disconnect, Feed Through | Open | 3; 1 Grounded | 6.2mm | Push In | 30 A | 500V | 5 | 5 A | 600V | - | 10-24 AWG | Gray | 0.2-6mm² | - |
|
NSYTRV62TTSCRW TMNL FD THRGH MSRNG TRNSDCR |
2,775 |
|
Datasheet |
Linergy TR | Box | Active | Feed Through | - | 1 | 8.2mm | Screw | 30 A | 500V | 2 | 30 A | 600V | - | - | Gray | 0.2-10mm² | - |
|
282-687/999-9503-CONDUCTOR GROUND TERMINAL BLOC |
4,005 |
|
Datasheet |
- | Box | Active | Ground, Earth | - | 1 | 8.0mm | Push In, Spring | - | - | 3 | - | - | - | 10-24 AWG | Green, Yellow | 0.2-6mm² | - |
|
281-6722-CONDUCTOR DISCONNECT TERMINAL |
3,699 |
|
Datasheet |
- | Box | Active | Disconnect | Fuse, Removable Plug | 1 | 8.0mm | Push In, Spring | 16 A | 800V | 2 | - | - | - | 12-28 AWG | Orange | 0.08-4mm² | - |
|
67601493CONN TERM BLK DISCONNECT 6-18AWG |
4,478 |
|
Datasheet |
USI 16 | - | Obsolete | Disconnect | Fuse, Lever | 1 | 17.7mm | Screw | - | - | 2 | 30 A | 600V | 1.5" x 13/32" | 6-18 AWG | White | - | - |
|
281-915/281-411COMPONENT TERMINAL BLOCK; 2-COND |
3,294 |
|
Datasheet |
- | Box | Active | Feed Through | - | 1 | 6.0mm | Push In, Spring | 500 mA | - | 2 | - | - | - | 12-28 AWG | Gray | 0.08-4mm² | Diode |