Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
VSBU-120-T3512BAC/DC CONVERTER 3.3V 5V 12V 120W |
46 |
|
![]() Datasheet |
VSBU-120-T (120W) | Box | Not For New Designs | Open Frame | 3 | 90 ~ 260 VAC | 3.3V | 5V | 12V | - | - | - | 15 A | 6 A | 1 A | - | - | - | 120W | ITE (Commercial) | 4.242 kV | 0°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.28" H (127.0mm x 76.2mm x 32.5mm) |
![]() |
MB120S15K01AC/DC CONVERTER 15V 99W |
76 |
|
![]() Datasheet |
MB120S (120W) | Box | Active | Open Frame | 1 | 80 ~ 264 VAC | 15V | - | - | - | - | - | 6.6 A | - | - | - | - | - | 99W (120W Forced Air) | Medical | 4000 V | -10°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.25" H (101.6mm x 50.8mm x 31.8mm) |
![]() |
ENP-180-24AC/DC CONVERTER 27.6V 179W |
114 |
|
![]() Datasheet |
ENP-180 (180W) | Box | Active | Enclosed | 1 | 90 ~ 264 VAC, 127 ~ 370 VDC | 27.6V | - | - | - | - | - | 6.5 A | - | - | - | - | - | 179W | ITE (Commercial) | 3 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Benchtop | 7.56" L x 7.01" W x 1.79" H (192.0mm x 178.0mm x 45.5mm) |
![]() |
SLB300S48CAC/DC CONVERTER 48V 202W |
31 |
|
![]() Datasheet |
SLB300 (300W) | Box | Active | Open Frame | 1 | 100 ~ 240 VAC, 120 ~ 370 VDC | 48V | - | - | - | - | - | 4.2 A | - | - | - | - | - | 202W (300W Forced Air) | ITE (Commercial), Medical | 4 kV | -10°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.40" H (127.0mm x 76.2mm x 35.6mm) |
![]() |
MDS-200ADB12 AAAC/DC CONVERTER 12V 110W |
119 |
|
![]() Datasheet |
MDS-200 (200W) | Box | Active | Enclosed | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 9.17 A | - | - | - | - | - | 110W (200W Forced Air) | ITE (Commercial), Medical | 4 kV | -10°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 4.48" L x 2.55" W x 1.76" H (113.9mm x 64.7mm x 44.7mm) |
![]() |
CFM130M120-CAC/DC CONVERTER 12V 100W |
43 |
|
![]() Datasheet |
CFM130M (130W) | Box | Active | Enclosed | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | - | 8.34 A | - | - | - | - | - | 100W (130W Forced Air) | Household Appliances, Medical | 4 kV | -30°C ~ 70°C (With Derating) | PFC, Universal Input | Chassis Mount | 3.60" L x 2.52" W x 1.36" H (91.4mm x 64.0mm x 34.5mm) |
![]() |
ULP180-1030AC/DC CONVERTER 30V 120W |
71 |
|
![]() Datasheet |
ULP180 (180W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 30V | - | - | - | - | - | 4 A | - | - | - | - | - | 120W (180W Forced Air) | ITE (Commercial) | 3 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) |
![]() |
LFMWLT150-1000AC/DC CONVERTER 5V 80W |
96 |
|
![]() Datasheet |
MWLT150 (150W) | Bulk | Active | Open Frame | 1 | 90 ~ 264 VAC, 120 ~ 390 VDC | 5V | - | - | - | - | - | 16 A | - | - | - | - | - | 80W (100W Forced Air) | Medical | 5.9 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) |
![]() |
LFMWLT150-1004AC/DC CONVERTER 48V 100W |
36 |
|
![]() Datasheet |
MWLT150 (150W) | Bulk | Active | Open Frame | 1 | 90 ~ 264 VAC, 120 ~ 390 VDC | 48V | - | - | - | - | - | 2.08 A | - | - | - | - | - | 100W (150W Forced Air) | Medical | 5.9 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.32" H (101.6mm x 50.8mm x 33.6mm) |
![]() |
MULP180-1348AC/DC CONVERTER 48V 120W |
72 |
|
![]() Datasheet |
MULP180 (180W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 48V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 120W (180W Forced Air) | Medical | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) |
![]() |
MULP180-0312AC/DC CONVERTER 12V 120W |
66 |
|
![]() Datasheet |
MULP180 (180W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W (180W Forced Air) | Medical | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.50" W x 0.75" H (101.6mm x 63.5mm x 19.1mm) |
![]() |
MULP180-1324AC/DC CONVERTER 24V 120W |
42 |
|
![]() Datasheet |
MULP180 (180W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 24V | - | - | - | - | - | 5 A | - | - | - | - | - | 120W (180W Forced Air) | Medical | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 0.75" H (101.6mm x 50.8mm x 19.1mm) |
![]() |
LFMWLT200-1001AC/DC CONVERTER 12V 160W |
49 |
|
![]() Datasheet |
MWLT200 (200W) | Bulk | Active | Enclosed | 1 | 90 ~ 264 VAC, 120 ~ 390 VDC | 12V | - | - | - | - | - | 13.33 A | - | - | - | - | - | 160W (200W Forced Air) | Medical | 5.9 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.1mm) |
![]() |
HEP-150-54AAC/DC CONVERTER 54V 151W |
42 |
|
![]() Datasheet |
HEP-150 (150W) | Box | Active | Enclosed | 1 | 90 ~ 305 VAC, 127 ~ 431 VDC | 54V | - | - | - | - | - | 2.8 A | - | - | - | - | - | 151W | ITE (Commercial) | 3.75 kV | -55°C ~ 70°C (With Derating) | Adjustable Output, IP65, PFC | Chassis Mount | 8.98" L x 2.68" W x 1.53" H (228.0mm x 68.0mm x 38.8mm) |
![]() |
RPS-400-36-CAC/DC CONVERTER 36V 252W |
27 |
|
![]() Datasheet |
RPS-400 (400W) | Box | Active | Enclosed | 1 | 80 ~ 264 VAC, 113 ~ 370 VDC | 36V | - | - | - | - | - | 7 A | - | - | - | - | - | 252W (403W Forced Air) | Medical | 4 kV | -30°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 5.11" L x 3.39" W x 1.69" H (129.8mm x 86.1mm x 42.9mm) |
![]() |
MB120S24C01AC/DC CONVERTER 24V 98W |
68 |
|
![]() Datasheet |
MB120S (120W) | Box | Active | Open Frame | 1 | 80 ~ 264 VAC | 24V | - | - | - | - | - | 4.1 A | - | - | - | - | - | 98W (120W Forced Air) | Medical | 4 kV | -10°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.25" H (101.6mm x 50.8mm x 31.8mm) |
![]() |
MB120S12C01AC/DC CONVERTER 12V 100W |
51 |
|
![]() Datasheet |
MB120S (120W) | Box | Active | Open Frame | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | - | 8.3 A | - | - | - | - | - | 100W (120W Forced Air) | Medical | 4 kV | -10°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.25" H (101.6mm x 50.8mm x 31.8mm) |
![]() |
PMF-5V320WCGBAC/DC CONVERTER 5V 320W |
60 |
|
![]() Datasheet |
PMF (275W) | Bulk | Active | Enclosed | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 55 A | - | - | - | - | - | 320W | ITE (Commercial) | 3 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.46" L x 4.53" W x 1.97" H (215.0mm x 115.0mm x 50.0mm) |
![]() |
LFMWLP225-1301AC/DC CONVERTER 12V 120W |
29 |
|
![]() Datasheet |
MWLP225 (225W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC, 390VDC | 12V | - | - | - | - | - | 10 A | - | - | - | - | - | 120W (225W Forced Air) | Medical | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 25.4mm) |
![]() |
ULP275-0058AC/DC CONVERTER 58V 160W |
41 |
|
![]() Datasheet |
ULP275 (275W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC, 390VDC | 58V | - | - | - | - | - | 2.76 A | - | - | - | - | - | 160W (275W Forced Air) | ITE (Commercial) | 3 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.50" W x 0.75" H (127.0mm x 88.9mm x 19.1mm) |