Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SWF150P-24AC/DC CONVERTER 24V 150W |
175 |
|
![]() Datasheet |
SWF150P (150W) | Bulk | Obsolete | Open Frame | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 6.3 A | - | - | - | - | - | 150W | ITE (Commercial) | 3 kV | -10°C ~ 70°C | Adjustable Output, Universal Input | Chassis Mount | 6.30" L x 2.95" W x 1.46" H (160.0mm x 75.0mm x 37.0mm) |
![]() |
LOF225-20B24-CAC/DC CONVERTER 24V 140W |
84 |
|
![]() Datasheet |
LOF225-20Bxx-C (225W) | Box | Not For New Designs | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 5.83 A | - | - | - | - | - | 140W | Household Appliances, ITE (Commercial), Medical | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.07" L x 2.44" W x 1.46" H (103.4mm x 62.0mm x 37.0mm) |
![]() |
VOF-100C-24-CNFAC/DC CONVERTER 24V 100W |
39 |
|
![]() Datasheet |
VOF-100C-CNF (100W) | Box | Not For New Designs | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 24V | - | - | - | - | - | 4.16 A | - | - | - | - | - | 100W | Household Appliances, ITE (Commercial) | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 3.15" L x 2.44" W x 1.57" H (80.0mm x 62.0mm x 40.0mm) |
|
EML15US12-SAC/DC CONVERTER 12V 15W |
167 |
|
![]() Datasheet |
EML15 (15W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 1.25 A | - | - | - | - | - | 15W | Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 3.30" L x 1.36" W x 1.04" H (84.0mm x 34.5mm x 26.4mm) |
![]() |
LCA50S-12AC/DC PS (OPEN FRAME) |
155 |
|
![]() Datasheet |
LCA (50W) | Box | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
GLC50-48GAC/DC CONVERTER 48V 50W |
0 |
|
![]() Datasheet |
GLC50 (50W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 1.1 A | - | - | - | - | - | 50W | ITE (Commercial) | - | 0°C ~ 50°C | Adjustable Output, Universal Input | Chassis Mount | 4.25" L x 2.50" W x 1.25" H (108.0mm x 63.5mm x 31.8mm) |
![]() |
LOF225-20B36-CAC/DC CONVERTER 36V 140W |
50 |
|
![]() Datasheet |
LOF225-20Bxx-C (225W) | Box | Not For New Designs | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 36V | - | - | - | - | - | 3.88 A | - | - | - | - | - | 140W | Household Appliances, ITE (Commercial), Medical | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 4.07" L x 2.44" W x 1.46" H (103.4mm x 62.0mm x 37.0mm) |
![]() |
MINT1065A4875C01AC/DC CONVERTER 48V 65W |
0 |
|
![]() Datasheet |
MINT1065 (65W) | Bulk | Obsolete | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 1 A | - | - | - | - | - | 65W | ITE (Commercial), Medical | 4 kV | 0°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.02" H (101.6mm x 50.8mm x 26.0mm) |
![]() |
ECP40UD01AC/DC CONVERTER 5V 12V 40W |
306 |
|
![]() Datasheet |
ECP (40W) | Box | Active | Open Frame | 2 | 85 ~ 264 VAC | 5V | 12V | - | - | - | - | 5 A | 2 A | - | - | - | - | 40W | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Universal Input | Chassis Mount | 3.50" L x 2.00" W x 1.01" H (88.9mm x 50.8mm x 26.0mm) |
![]() |
CFM150M360AC/DC CONVERTER 36V 150W |
53 |
|
![]() Datasheet |
CFM150M (150W) | Box | Obsolete | Open Frame | 1 | 90 ~ 264 VAC | 36V | - | - | - | - | - | 4.17 A | - | - | - | - | - | 150W | ITE (Commercial), Medical | 5.656 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.05" H (127.0mm x 76.2mm x 26.7mm) |
![]() |
LFWLP75-1001AC/DC CONVERTER 12V 75W |
82 |
|
![]() Datasheet |
WLP75 (75W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC, 390VDC | 12V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 75W | ITE (Commercial) | 3 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, PFC, Standby Output, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.00" H (76.2mm x 50.8mm x 25.4mm) |
|
LPS48AC/DC CONVERTER 48V 40W |
240 |
|
![]() Datasheet |
LPS40 (40W) | Bulk | Obsolete | Open Frame | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 900 mA | - | - | - | - | - | 40W (55W Forced Air) | ITE (Commercial) | - | 0°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.14" H (127.0mm x 76.2mm x 29.0mm) |
|
LPT63AC/DC CONVERTER 5V +/-15V 60W |
49 |
|
![]() Datasheet |
LPT60 (60W) | Bulk | Obsolete | Open Frame | 3 | 85 ~ 264 VAC | 5V | 15V | -15V | - | - | - | 7 A | 2.8 A | 700 mA | - | - | - | 60W (80W Forced Air) | ITE (Commercial) | - | 0°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.69" H (127.0mm x 76.2mm x 42.9mm) |
![]() |
PMT-24V350W1AKAC/DC CONVERTER 24V 350W |
610 |
|
![]() Datasheet |
PMT (350W) | Bulk | Obsolete | Enclosed | 1 | 90 ~ 132 VAC, 180 ~ 264 VAC | 24V | - | - | - | - | - | 14.6 A | - | - | - | - | - | 350W | ITE (Commercial) | 3 kV | -10°C ~ 70°C (With Derating) | Adjustable Output | Chassis Mount | 8.46" L x 4.53" W x 1.97" H (215.0mm x 115.0mm x 50.0mm) |
![]() |
1011332GRN-60-1002 |
50 |
|
![]() Datasheet |
GRN-60 (60W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 5V | - | - | - | - | - | 9 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) |
![]() |
1011360GRN-60-1008 |
50 |
|
![]() Datasheet |
GRN-60 (60W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 19V | - | - | - | - | - | 3.1 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) |
![]() |
1011333GRN-60-1003 |
50 |
|
![]() Datasheet |
GRN-60 (60W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 5 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) |
![]() |
1011337GRN-60-1007 |
50 |
|
![]() Datasheet |
GRN-60 (60W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 1.3 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) |
![]() |
1011334GRN-60-1004 |
33 |
|
![]() Datasheet |
GRN-60 (60W) | Box | Active | Open Frame | 1 | 85 ~ 264 VAC | 15V | - | - | - | - | - | 4 A | - | - | - | - | - | 60W | ITE (Commercial), Medical | - | 0°C ~ 70°C (With Derating) | Adjustable Output, Remote Sense, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 0.83" H (76.2mm x 50.8mm x 21.1mm) |
![]() |
VOF-225C-36AC/DC CONVERTER 36V 225W |
30 |
|
![]() Datasheet |
VOF-225C (225W) | Tray | Not For New Designs | Open Frame | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 36V | - | - | - | - | - | 6.25 A | - | - | - | - | - | 225W | Household Appliances, ITE (Commercial) | 4 kV | -40°C ~ 70°C (With Derating) | Adjustable Output, Standby Output, Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.00" H (101.6mm x 50.8mm x 25.4mm) |