Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CS10S-24NS1-B1000W, 24V FANLESS SRANDARD, CON EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10S-24NS0-A1000W, 24V FANLESS SRANDARD, CON EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10S-48NS0-A1000W, 48V FANLESS SRANDARD, CON EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10S-48NS0-B1000W, 48V FANLESS SRANDARD, CON EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
XB1000-24N-007BF READY 1000W, 24V STANDARD FAN EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
Xsolo (1000W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 380 VDC | 24V | - | - | - | - | - | 42 A | - | - | - | - | - | 1008W | ITE (Commercial), Medical | 4 kV | 0°C ~ 70°C (With Derating) | Adjustable Output, Baseplate, DC Input Capable, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 9.37" L x 5.04" W x 1.60" H (238.0mm x 128.0mm x 40.6mm) |
![]() |
XB1000-48N-007BF READY 1000W, 48V STANDARD FAN EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
Xsolo (1000W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 380 VDC | 48V | - | - | - | - | - | 21 A | - | - | - | - | - | 1008W | ITE (Commercial), Medical | 4 kV | 0°C ~ 70°C (With Derating) | Adjustable Output, Baseplate, DC Input Capable, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | - |
![]() |
CS10S-48N-1-B1000W, 48V FANLESS SRANDARD, IEC EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10S-24N-1-A1000W, 24V FANLESS SRANDARD, IEC EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10S-48N-1-A1000W, 48V FANLESS SRANDARD, IEC EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10S-48N-0-B1000W, 48V FANLESS SRANDARD, SCR EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |