Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CS10M-48NS1-B1000W, 48V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-24NS1-B1000W, 24V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-48NS0-A1000W, 48V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-24NS0-B1000W, 24V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-48NS0-B1000W, 48V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-48NS1-A1000W, 48V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-24NS14A1000W, 24V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-48NS04A1000W, 48V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-24NS04A1000W, 24V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 41.6 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |
![]() |
CS10M-48NS14A1000W, 48V FANLESS MEDICAL, CONF EXCELSYS / Advanced Energy |
0 |
|
![]() Datasheet |
CS1000 (1000W) | Box | Active | Enclosed, Conformal Coated | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 20.8 A | - | - | - | - | - | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C (With Derating) | Adjustable Output, PMBus™, Remote Sense, Universal Input | Chassis Mount | 10.30" L x 5.00" W x 1.54" H (261.6mm x 127.0mm x 39.1mm) |