| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Part Status | For Measuring | Sensor Type | Number of Channels | Output | Sensitivity | Polarization | Frequency | Linearity | Current - Sensing | Accuracy | Voltage - Supply | Qualification | Response Time | Mounting Style | Grade | Current - Supply (Max) | Operating Temperature | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR5210-20HALL EFF CURRENT TRANSDUCERS 24V |
4,077 |
|
Datasheet |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CR5210-30SENSOR CURRENT HALL 30A DC |
2,944 |
|
Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 1 | Ratiometric, Voltage | - | Unidirectional | DC | - | 30A | ±1% | 24V | - | 250ms | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR5410-100SENSOR CURRENT HALL 100A AC/DC |
3,491 |
|
Datasheet |
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 4kHz | - | 100A | ±1% | 24V | - | - | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR5410-150SENSOR CURRENT HALL 150A AC/DC |
3,622 |
|
Datasheet |
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 4kHz | - | 150A | ±1% | 24V | - | - | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR5410-75SENSOR CURRENT HALL 75A AC/DC |
2,637 |
|
Datasheet |
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 4kHz | - | 75A | ±1% | 24V | - | - | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR5210-100SENSOR CURRENT HALL 100A DC |
3,318 |
|
Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 1 | Ratiometric, Voltage | - | Unidirectional | DC | - | 100A | ±1% | 24V | - | 250ms | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR5210-300SENSOR CURRENT HALL 300A DC |
3,682 |
|
Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 1 | Ratiometric, Voltage | - | Unidirectional | DC | - | 300A | ±1% | 24V | - | 250ms | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR5210-75SENSOR CURRENT HALL 75A DC |
3,455 |
|
Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 1 | Ratiometric, Voltage | - | Unidirectional | DC | - | 75A | ±1% | 24V | - | 250ms | DIN Rail, Panel | - | 40mA | 0°C ~ 50°C | - |
|
CR4220S-40SENSOR CURRENT XFMR 40A AC |
4,230 |
|
Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 40A | ±0.5% | 24V | - | 250ms | DIN Rail | - | - | 0°C ~ 60°C | - |
|
CR4220S-50SENSOR CURRENT XFMR 50A AC |
2,785 |
|
Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 4mA ~ 20mA | - | Bidirectional | 50Hz ~ 400Hz | - | 50A | ±0.5% | 24V | - | 250ms | DIN Rail | - | - | 0°C ~ 60°C | - |
|
HAX 2000-S/SP18TRANSDUCER |
2,234 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ARU-B100-D125SENSOR |
3,817 |
|
Datasheet |
ARU | Module | Bulk | Active | AC | Rogowski Coil | 1 | Voltage | 0.1mV/A | Unidirectional | 519kHz | - | 1000A | ±0.5% | - | - | - | Chassis Mount | - | - | -40°C ~ 80°C | - |
|
LTC 400-SFTRANSDUCER |
4,382 |
|
Datasheet |
LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 400A | ±0.6% | ±15V ~ 24V | - | 1µs | Chassis Mount | - | - | -40°C ~ 85°C | - |
|
S29S1T0D24ZMSENSOR CURRENT HALL 1000A AC/DC |
2,457 |
|
Datasheet |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Ratiometric, Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 1000A | ±0.1% | ±15V ~ 24V | - | 1µs | - | - | 200mA | -40°C ~ 85°C | - |
|
S29S1T0D24ZSENSOR |
3,142 |
|
Datasheet |
- | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Ratiometric, Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 1000A | ±0.1% | ±15V ~ 24V | - | 1µs | - | - | 200mA | -40°C ~ 85°C | - |
|
S29S1T0D24ZJSENSOR |
3,339 |
|
Datasheet |
- | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Closed Loop | 1 | Ratiometric, Current | - | Bidirectional | DC ~ 100kHz | ±0.1% | 1000A | ±0.1% | ±15V ~ 24V | - | 1µs | - | - | 200mA | -40°C ~ 85°C | - |
|
LF 1010-S/SP41TRANSDUCER |
2,267 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 1 | Current | 0.2mA/A | Bidirectional | DC ~ 200kHz | ±0.15% | 1000A | ±0.4% | ±25.2V | - | 500ns | Chassis Mount | - | 49mA | -40°C ~ 85°C | - |
|
LF 1010-S/SPA4TRANSDUCER |
2,322 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1010-S/SPA2TRANSDUCER |
2,809 |
|
Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Current | 0.2mA/A | Bidirectional | 200kHz | ±0.15% | 1000A | ±0.4% | ±14.25V ~ 25.2V | - | 500ns | Chassis Mount | - | 49mA | -40°C ~ 85°C | - |
|
LF 505-S/SP15CLOSED LOOP CURRENT SENSOR |
2,077 |
|
- |
* | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |