Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CR5211-150SENSOR CURRENT HALL 150A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
CR5211-75SENSOR CURRENT HALL 75A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 75A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
CR5211-50SENSOR CURRENT HALL 50A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 50A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
CR5211-100SENSOR CURRENT HALL 100A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
CR5211-300SENSOR CURRENT HALL 300A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
CR5211-30SENSOR CURRENT HALL 30A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Hall Effect, Closed Loop | 30A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
CR5211-5SENSOR CURRENT MAGNETIC 5A DC |
0 |
|
![]() Datasheet |
CR5200 | Module | Bulk | Active | DC | Magnetic Modulator, Closed Loop | 5A | 1 | Ratiometric, ±10V | - | DC | - | ±1% | 24V | 250ms | 40mA | 0°C ~ 50°C | - | - | Unidirectional | DIN Rail, Panel | - |
![]() |
HAX 2500-S/SP18TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LF 505-S/SP26TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LF 1010-S/SPA5TRANSDUCER |
0 |
|
![]() Datasheet |
LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | 0.2mA/A | 200kHz | ±0.15% | ±0.4% | 14.25V ~ 25.2V | 500ns | 49mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
CSNS300F-003300A NULL BALANCE CURRENT SENSOR |
0 |
|
- |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
A/CTE2-50Analog Current Sensor, 0-5 VDC, |
1 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | AC | Current Sensor | 10A, 20A, 50A (Selectable) | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 600Hz | - | ±1% | 600VAC | 300ms | - | -15°C ~ 40°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
CR4410-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
![]() Datasheet |
CR4400 | Module | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 40mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
![]() |
LA 305-S/SP17SENSORS |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
CR5411-20AC/DC HALL EFFECT TRANSDUCER 20A |
0 |
|
- |
CR5400 | Module | Bulk | Active | AC/DC | Hall Effect | 20A | 1 | Analog Voltage | - | DC ~ 4kHz | - | ±1% | 21.6V ~ 26.4V | - | - | 0°C ~ 50°C | - | - | Bidirectional | DIN Rail | - |
![]() |
CR5411-100SENSOR CURRENT HALL 100A AC/DC |
0 |
|
- |
* | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LF 505-S/SP22TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
CR4210S-5SENSOR CURRENT XFMR 5A AC |
0 |
|
![]() Datasheet |
CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
![]() |
HTC 500-S/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LF 505-S/SP2TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |