| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Part Status | Type | Unidirectional Channels | Voltage - Reverse Standoff (Typ) | Voltage - Breakdown (Min) | Voltage - Clamping (Max) @ Ipp | Supplier Device Package | Current - Peak Pulse (10/1000µs) | Power - Peak Pulse | Bidirectional Channels | Power Line Protection | Part Applications | Mounting Style | Capacitance @ Frequency | Qualification | Operating Temperature | Grade |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
P4KE170A/BTVS DO-204AL 145V 234V BOX |
2,412 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 145V | 162V | 234V | DO-204AL (DO-41) | 1.8A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE91A/BTVS DO-204AL 77.8V 125V BOX |
4,310 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 77.8V | 86.5V | 125V | DO-204AL (DO-41) | 3.3A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE56CA/BTVS DO-204AL 47.8V 77V BOX |
3,313 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 47.8V | 53.2V | 77V | DO-204AL (DO-41) | 5.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE170CA/BTVS DO-204AL 145V 234V BOX |
4,634 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 145V | 162V | 234V | DO-204AL (DO-41) | 1.8A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE20A/BTVS DO-204AL 17.1V 27.7V BO |
2,229 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 17.1V | 19V | 27.7V | DO-204AL (DO-41) | 14.8A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE36A/BTVS DO-204AL 30.8V 49.9V BO |
4,245 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 30.8V | 34.2V | 49.9V | DO-204AL (DO-41) | 8.2A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE100A/BTVS DO-204AL 85.5V 137V BOX |
3,536 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 85.5V | 95V | 137V | DO-204AL (DO-41) | 3A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE22A/BTVS DO-204AL 18.8V 30.6V BO |
2,946 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 18.8V | 20.9V | 30.6V | DO-204AL (DO-41) | 13.4A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE8.2CA/BTVS DO-204AL 7.02V 12.1V BO |
2,121 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 7.02V | 7.79V | 12.1V | DO-204AL (DO-41) | 33.9A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE150A/BTVS DO-204AL 128V 207V BOX |
2,768 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 128V | 143V | 207V | DO-204AL (DO-41) | 2A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE220CA/BTVS DO-204AL 185V 328V BOX |
2,478 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 185V | 209V | 328V | DO-204AL (DO-41) | 1.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE10CA/BTVS DO-204AL 8.55V 14.5V BO |
2,088 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 8.55V | 9.5V | 14.5V | DO-204AL (DO-41) | 28.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE200CA/BTVS DO-204AL 171V 274V BOX |
4,006 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 171V | 190V | 274V | DO-204AL (DO-41) | 1.5A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE8.2A/BTVS DO-204AL 7.02V 12.1V BO |
2,764 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 7.02V | 7.79V | 12.1V | DO-204AL (DO-41) | 33.9A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE27A/BTVS DO-204AL 23.1V 37.5V BO |
2,805 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 23.1V | 25.7V | 37.5V | DO-204AL (DO-41) | 10.9A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE120A/BTVS DO-204AL 102V 165V BOX |
3,731 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 102V | 114V | 165V | DO-204AL (DO-41) | 2.5A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE82A/BTVS DO-204AL 70.1V 113V BOX |
2,241 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 70.1V | 77.9V | 113V | DO-204AL (DO-41) | 3.6A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE130CA/BTVS DO-204AL 111V 179V BOX |
4,015 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 111V | 124V | 179V | DO-204AL (DO-41) | 2.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE100CA/BTVS DO-204AL 85.5V 137V BOX |
2,350 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 85.5V | 95V | 137V | DO-204AL (DO-41) | 3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE7.5CA/BTVS DO-204AL 6.4V 11.3V BOX |
3,708 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 6.4V | 7.13V | 11.3V | DO-204AL (DO-41) | 36.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |