| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Part Status | Type | Unidirectional Channels | Voltage - Reverse Standoff (Typ) | Voltage - Breakdown (Min) | Voltage - Clamping (Max) @ Ipp | Supplier Device Package | Current - Peak Pulse (10/1000µs) | Power - Peak Pulse | Bidirectional Channels | Power Line Protection | Part Applications | Mounting Style | Capacitance @ Frequency | Qualification | Operating Temperature | Grade |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
P4KE250A/BTVS DO-204AL 214V 344V BOX |
3,486 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 214V | 237V | 344V | DO-204AL (DO-41) | 1.2A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE47CA/BTVS DO-204AL 40.2V 64.8V BO |
4,308 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 40.2V | 44.7V | 64.8V | DO-204AL (DO-41) | 6.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE33A/BTVS DO-204AL 28.2V 45.7V BO |
3,078 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 28.2V | 31.4V | 45.7V | DO-204AL (DO-41) | 9A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE16CA/BTVS DO-204AL 13.6V 22.5V BO |
3,470 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 13.6V | 15.2V | 22.5V | DO-204AL (DO-41) | 18.2A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE110A/BTVS DO-204AL 94V 152V BOX |
3,116 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 94V | 105V | 152V | DO-204AL (DO-41) | 2.7A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE39A/BTVS DO-204AL 33.3V 53.9V BO |
3,171 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 33.3V | 37.1V | 53.9V | DO-204AL (DO-41) | 7.6A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE43A/BTVS DO-204AL 36.8V 59.3V BO |
4,505 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 36.8V | 40.9V | 59.3V | DO-204AL (DO-41) | 6.9A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE62A/BTVS DO-204AL 53V 85V BOX |
2,013 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 53V | 58.9V | 85V | DO-204AL (DO-41) | 4.8A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE51A/BTVS DO-204AL 43.6V 70.1V BO |
3,550 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 43.6V | 48.5V | 70.1V | DO-204AL (DO-41) | 5.8A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE24CA/BTVS DO-204AL 20.5V 33.2V BO |
3,711 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 20.5V | 22.8V | 33.2V | DO-204AL (DO-41) | 12.3A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE36CA/BTVS DO-204AL 30.8V 49.9V BO |
2,906 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 30.8V | 34.2V | 49.9V | DO-204AL (DO-41) | 8.2A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE160CA/BTVS DO-204AL 136V 219V BOX |
4,397 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 136V | 152V | 219V | DO-204AL (DO-41) | 1.9A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE180CA/BTVS DO-204AL 154V 246V BOX |
2,267 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 154V | 171V | 246V | DO-204AL (DO-41) | 1.7A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE7.5A/BTVS DO-204AL 6.4V 11.3V BOX |
2,144 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 6.4V | 7.13V | 11.3V | DO-204AL (DO-41) | 36.3A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE20CA/BTVS DO-204AL 17.1V 27.7V BO |
4,920 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 17.1V | 19V | 27.7V | DO-204AL (DO-41) | 14.8A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE68A/BTVS DO-204AL 58.1V 92V BOX |
4,165 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 58.1V | 64.6V | 92V | DO-204AL (DO-41) | 4.5A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE6.8CA/BTVS DO-204AL 5.8V 10.5V BOX |
4,064 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 5.8V | 6.45V | 10.5V | DO-204AL (DO-41) | 39A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE43CA/BTVS DO-204AL 36.8V 59.3V BO |
2,824 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 36.8V | 40.9V | 59.3V | DO-204AL (DO-41) | 6.9A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE110CA/BTVS DO-204AL 94V 152V BOX |
2,931 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | - | 94V | 105V | 152V | DO-204AL (DO-41) | 2.7A | 400W | 1 | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |
|
P4KE16A/BTVS DO-204AL 13.6V 22.5V BO |
4,184 |
|
Datasheet |
DO-204AL, DO-41, Axial | P4KE | Tape & Box (TB) | Active | Zener | 1 | 13.6V | 15.2V | 22.5V | DO-204AL (DO-41) | 18.2A | 400W | - | No | General Purpose | Through Hole | - | - | -55°C ~ 150°C (TJ) | - |